Yamamoto H, Iyori H, Kanomi R, Yao K, Hieda T
Kanomi Pediatric Dental Clinic.
Shoni Shikagaku Zasshi. 1990;28(3):725-31.
Although composite resin has been used as an aesthetic restorative material, wear and fracture of the resin of fracture of the tooth structure are likely to occur when the size of the dental cavities are large. In addition to the lack of the aesthetic value, clinical results of prefabricated metal crown revealed several problems which were caused by the wear of the metal and the ill-adaptation of the cervical margin. In the present study, 50 devitalized deciduous molars were treated with composite resin onlays which were designed to cover the entire occlusal surface of the deciduous molar, and the clinical results were evaluated for a 6 month period. Additionally, for the purpose of simplification of the laboratory process for making resin onlays, ready-made occlusal shells were fabricated. The variety of the prepared shell size consisted of 7 sizes for the first deciduous molar, 9 sizes for the upper second deciduous molar and 10 sizes for the lower deciduous molar. The following results were obtained. 1) A partial resin fracture at the peripheral area of the mesio-buccal cuspid was found in five cases out of 50. 2) A glossy appearance on the surface of the onlay which was created by coated unfilled resin disappeared after 6 months of observation. 3) In relation to the resin onlay, when the antagonistic tooth was restored with prefabricated metal crowns, holes were made by attrition on all the crowns within a 3-4 month period.(ABSTRACT TRUNCATED AT 250 WORDS)