Suppr超能文献

轻松实现主动脉-冠状动脉静脉“Y”型吻合。

Aorto-coronary vein graft 'Y' anastomosis made easy.

机构信息

Department of Cardiothoracic Surgery, Castle Hill Hospital, Castle Road, Cottingham, East Yorkshire, HU16 5JQ, UK.

出版信息

Eur J Cardiothorac Surg. 2011 Oct;40(4):1027-8. doi: 10.1016/j.ejcts.2011.01.012. Epub 2011 Feb 24.

Abstract

Vein graft-to-vein graft anastomosis, creating a 'Y' graft, is a useful technique when there is a lack of good-quality autologous vein to perform individual aorto-coronary bypass grafts or when the ascending aorta is short or atheromatous, limiting the space for proximal graft anastomosis. Unlike artery-to-artery composite grafts, which are resistant to flow-limiting technique-based distortions, the accurate construction of vein-to-vein anastomoses is critical. A technique is described that facilitates accurate placement of the anastomosis that prevents kinking, twisting or displacement.

摘要

静脉-静脉吻合,形成“Y”型移植物,当缺乏高质量自体静脉进行单个主动脉-冠状动脉旁路移植术,或升主动脉短或粥样硬化,限制近端移植物吻合空间时,是一种有用的技术。与抗血流限制技术扭曲的动脉-动脉复合移植物不同,准确构建静脉-静脉吻合至关重要。本文描述了一种有助于防止吻合处扭曲、扭转或移位的准确吻合技术。