Punke John P, Fox Derek B, Tomlinson James L, Davis J Wade, Mann F A
Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211, USA.
Vet Surg. 2011 Jul;40(5):555-62. doi: 10.1111/j.1532-950X.2011.00802.x. Epub 2011 Mar 1.
To determine which of 3 different plate angles (20°, 25°, 30°) used in double pelvic osteotomy (DPO) would result in the most similar acetabular angle (AA) achieved with a 20° triple pelvic osteotomy (TPO) technique in dogs.
Experimental anatomic study.
Cadaveric canine pelves (n = 8).
Transverse plane computed tomographic images of cadaveric pelves with intact sacroiliac joints, mounted in a custom jig, were made (baseline) and again after DPO (20°, 25°, 30°) and TPO (20°) and pelvic angles measured in 6 transverse planes. Pelvic angles of the 3 DPO techniques were compared with TPO using concordance correlation to determine which DPO angle resulted in an acetabular ventroversion angle closest to TPO.
Mean ± SD AAs were 32.89 ± 2.23 (baseline), 47.39 ± 4.39 (20° DPO), 51.43 ± 5.06 (25° DPO), 54.75 ± 4.38 (30° DPO), and 50.20 ± 5.76 (20° TPO). Concordance correlations for the AA compared with 20° TPO were 0.027 (baseline), 0.721 (20° DPO), 0.902 (25° DPO), and 0.593 (30° DPO). A concordance correlation of ≥ 0.8 indicates good correlation.
A 25° DPO is most similar in acetabular ventroversion to 20° TPO (concordance correlation, 0.902).
确定在双骨盆截骨术(DPO)中使用的3种不同钢板角度(20°、25°、30°)中,哪一种能使犬类达到与20°三骨盆截骨术(TPO)技术最相似的髋臼角(AA)。
实验解剖学研究。
犬类尸体骨盆(n = 8)。
对安装在定制夹具中的、骶髂关节完整的犬类尸体骨盆进行横断面计算机断层扫描成像(基线),在DPO(20°、25°、30°)和TPO(20°)后再次成像,并在6个横断面上测量骨盆角度。使用一致性相关性将3种DPO技术的骨盆角度与TPO进行比较,以确定哪种DPO角度能产生最接近TPO的髋臼前倾角。
平均±标准差的髋臼角分别为32.89±2.23(基线)、47.39±4.39(20° DPO)、51.43±5.06(25° DPO)、54.75±4.38(30° DPO)和50.20±5.76(20° TPO)。与20° TPO相比,髋臼角的一致性相关性分别为0.027(基线)、0.721(20° DPO)、0.902(25° DPO)和0.593(30° DPO)。一致性相关性≥0.8表明相关性良好。
25° DPO在髋臼前倾角方面与20° TPO最相似(一致性相关性,0.902)。