INTRODUCTION

Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral free- end saddle denture without major connector was taken into consideration.

OBJECTIVE

The aim was to analyze and compare a unilateral RPD (removable partial denture) and a classical RPD by calculating and analyzing stresses under different loads.

METHODS

3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made). The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar.

RESULTS

The Fault Model Extractor (FME) analysis and calculation showed the complete behaviour of unilateral removable partial denture and abutments (canine and first premolar), as well as the behaviour of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits.

CONCLUSION

Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values

摘要

引言

在单侧游离端鞍基义齿修复治疗中会使用各种移动设备。带有精确连接部件的单侧义齿并不常用。本文考虑了无大连接体的单侧游离端鞍基义齿的应用问题及其功能。

目的

通过计算和分析不同载荷下的应力,分析和比较单侧可摘局部义齿(RPD)和传统RPD。

方法

使用计算机程序CATIA V5制作单侧可摘局部义齿和带有铸造卡环的传统可摘局部义齿的三维模型(还制作了基牙、尖牙和第一前磨牙以及它们的牙冠和基牙组织)。模型按实际尺寸构建。通过在第二前磨牙上施加300N的力、在第一磨牙上施加500N的力以及在第二磨牙上施加700N的力,对两个模型进行应力分析。

结果

故障模型提取器(FME)分析和计算显示了单侧可摘局部义齿和基牙(尖牙和第一前磨牙)的完整行为,以及相同加载条件下RPD的行为。施加的极值力在生理极限范围内使两个模型及其基牙产生了高应力水平。

结论

在相同条件下分析应力后,我们得出结论,单侧RPD和传统RPD具有相似的生理值