Suppr超能文献

离子对固相萃取-高效液相色谱法测定直链烷基苯磺酸盐。

Determination of linear alkylbenzene sulfonates by ion-pair solid-phase extraction and high-performance liquid chromatography.

机构信息

The Key Laboratory of Eco-environments in Three Gorges Reservoir Region (Ministry of Education), College of Chemistry and Chemical Engineering, Southwest University; Chongqing 400715, China.

出版信息

Talanta. 2011 Apr 15;84(2):587-92. doi: 10.1016/j.talanta.2011.01.014. Epub 2011 Jan 15.

Abstract

In this paper, the potential use of multiwalled carbon nanotubes (MWCNTs) as solid phase extraction (SPE) adsorbent was evaluated for preconcentration of linear alkylbenzene sulfonates (LAS) using ion-pair (IP)-SPE with tetrabutylammonium hydroxide (TBAH). The LAS homologues present in the aqueous sample were ion-paired with TBAH and the solution was passed through the MWCNT cartridges. The analytes retained in the cartridge were eluted with methanol and the concentrated methanol extract was analysed by HPLC-UV. In order to obtain the satisfactory recovery of LAS homologues, various parameters including the type and amount of the ion-pair reagents, the desorption and enrichment conditions such as the effect of eluent and its volume, pH, the flow rate, the ultrasonic time of sample, and the volume of sample solution were systematically optimized. Under the optimal conditions, LAS homologues could be easily extracted by the proposed SPE cartridge. The favorable limits of detection (LOD) for LAS homologues were in the range from 0.02 to 0.03 μg L(-1), and the relative standard deviations (RSDs) were 1.55-2.54% for 10 μg L(-1) LAS (n=6). The proposed method has been successfully applied for the analysis of LAS homologues in aqueous environmental samples. A comparison study with ion-pair solid extraction on MWCNTs, C8 and C18 as adsorbents for LAS demonstrated that ion pair-based solid extraction on MWCNTs adsorbent was advantageous over C8 and C18, the widely used traditional adsorbents.

摘要

本文评估了多壁碳纳米管(MWCNTs)作为固相萃取(SPE)吸附剂,用于与四丁基氢氧化铵(TBAH)形成离子对(IP)-SPE 来预浓缩线性烷基苯磺酸盐(LAS)。水样中的 LAS 同系物与 TBAH 形成离子对,溶液通过 MWCNT 萃取柱。分析物保留在萃取柱中,用甲醇洗脱,浓缩的甲醇提取物通过 HPLC-UV 进行分析。为了获得 LAS 同系物的满意回收率,系统优化了各种参数,包括离子对试剂的类型和用量、洗脱和富集条件,如洗脱剂及其体积、pH 值、流速、样品超声时间和样品溶液体积的影响。在最佳条件下,所提出的 SPE 萃取柱可以轻松提取 LAS 同系物。LAS 同系物的有利检出限(LOD)在 0.02-0.03μg L(-1) 范围内,10μg L(-1)LAS(n=6)的相对标准偏差(RSD)为 1.55-2.54%。该方法已成功应用于水样中 LAS 同系物的分析。与 MWCNTs、C8 和 C18 上的离子对固相等离子对固相萃取的比较研究表明,MWCNTs 吸附剂上的基于离子对的固相萃取优于 C8 和 C18,这两种吸附剂是广泛使用的传统吸附剂。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验