Suppr超能文献

重金属阳离子的电膜萃取后,采用电容耦合非接触式电导检测的毛细管电泳法。

Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection.

机构信息

Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic.

出版信息

Electrophoresis. 2011 Apr;32(9):1025-32. doi: 10.1002/elps.201000462. Epub 2011 Mar 30.

Abstract

Electromembrane extraction (EME) was used as an off-line sample pre-treatment method for the determination of heavy metal cations in aqueous samples using CE with capacitively coupled contactless conductivity detection (CE-C(4) D). A short segment of porous polypropylene hollow fibre was penetrated with 1-octanol and 0.5% v/v bis(2-ethylhexyl)phosphonic acid and constituted a low cost, single use, disposable supported liquid membrane, which selectively transported and pre-concentrated heavy metal cations into the fibre lumen filled with 100 mM acetic acid acceptor solution. Donor solutions were standard solutions and real samples dissolved in deionized water at neutral pH. At optimized EME conditions (penetration time, 5 s; applied voltage, 75 V; and stirring rate, 750 rpm), 15-42% recoveries of heavy metal cations were achieved for a 5 min extraction time. Repeatability of the EME pre-treatment was examined for six independent EME runs and ranged from 6.6 to 11.1%. Limits of detection for the EME-CE-C(4) D method ranged from 25 to 200 nM, resulting into one to two orders of magnitude improvement compared with CE-C(4) D without sample treatment. The developed EME sample pre-treatment procedure was applied to the analysis of heavy metal cations in tap water and powdered milk samples. Zinc in the real samples was identified and quantified in a background electrolyte solution consisting of 20 mM L-histidine and 30 mM acetic acid at pH 4.95 in about 3 min.

摘要

电渗析萃取(EME)被用作一种离线样品预处理方法,用于使用带有电容耦合非接触式电导检测(CE-C(4)D)的 CE 测定水样中的重金属阳离子。一段短的多孔聚丙烯中空纤维被 1-辛醇和 0.5%v/v 双(2-乙基己基)膦酸穿透,构成了一种低成本、一次性使用、 disposable 支撑液膜,它选择性地将重金属阳离子运输并预浓缩到充满 100mM 乙酸接受溶液的纤维内腔中。供体溶液是标准溶液和溶解在中性 pH 去离子水中的实际样品。在优化的 EME 条件下(渗透时间 5s;施加电压 75V;搅拌速度 750rpm),对于 5min 的萃取时间,重金属阳离子的回收率为 15-42%。对六个独立的 EME 运行进行了 EME 预处理的重复性检查,范围为 6.6-11.1%。EME-CE-C(4)D 方法的检测限范围为 25-200nM,与没有样品处理的 CE-C(4)D 相比,提高了一个到两个数量级。开发的 EME 样品预处理程序被应用于自来水和奶粉样品中重金属阳离子的分析。在由 20mM L-组氨酸和 30mM 乙酸组成的背景电解质溶液中,锌在实际样品中的存在和定量在约 3min 内完成,pH 值为 4.95。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验