Department of Clinical Radiology, University Hospitals Munich-Grosshadern Campus, Ludwig Maximilians University, Marchioninistr. 15, 81377 Munich, Germany.
Eur Radiol. 2011 Aug;21(8):1667-76. doi: 10.1007/s00330-011-2110-x. Epub 2011 Apr 9.
To compare different techniques for carotid imaging including contrast-enhanced, unenhanced and dynamic techniques to find an alternative to contrast-enhanced MRA.
43 patients referred for imaging of the carotids were enrolled in this IRB-approved study. Imaging included dark-blood, time-of-flight, ECG-gated SSFP and dynamic and static contrast-enhanced MRA. Two radiologists evaluated all datasets in terms of image quality (vessel lumen, signal homogeneity, diagnostic confidence, preferred technique) on a four-point Likert-scale and in measuring the vessel area.
Of the 43 included patients the first 8 subjects served for protocol optimisation and 4 individuals discontinued the examination. Thus 31 datasets served for evaluation. CE-MRA revealed best results for delineation of vessel lumen, signal homogeneity and diagnostic confidence with values of 3.61, 3.42 and 3.77. It was also rated as the most preferred technique. SSFP-MRA was rated second in all categories with values of 3.1, 2.9 and 3.11. This unenhanced technique was the only one showing non-significantly different results in quantitative analysis.
SSFP-MRA, an unenhanced form of MRA, represents an alternative to CE-MRA, particularly in patients where administration of gadolinium for CE-MRA may be contraindicated. In contrast to other techniques, SSFP-MRA serves with not significant different results compared to standard CE-MRA.
比较颈动脉成像的不同技术,包括对比增强、非增强和动态技术,以寻找对比增强 MRA 的替代方法。
这项经过机构审查委员会批准的研究纳入了 43 名因颈动脉成像而就诊的患者。成像包括黑血、时飞、ECG 门控 SSFP 和动态及静态对比增强 MRA。两名放射科医生使用四点 Likert 量表评估所有数据集的图像质量(血管管腔、信号均匀性、诊断信心、首选技术)和测量血管面积。
在 43 名纳入的患者中,前 8 名患者用于协议优化,4 名患者中止了检查。因此,31 个数据集用于评估。CE-MRA 在血管管腔、信号均匀性和诊断信心方面的评估结果最好,其值分别为 3.61、3.42 和 3.77。它也被评为最受欢迎的技术。SSFP-MRA 在所有类别中的评分均为第二,其值分别为 3.1、2.9 和 3.11。这种非增强技术是唯一一种在定量分析中显示出无显著差异结果的技术。
SSFP-MRA 是一种非增强形式的 MRA,是 CE-MRA 的替代方法,特别是在因 CE-MRA 而可能需要钆剂的患者中。与其他技术相比,SSFP-MRA 的结果与标准 CE-MRA 无显著差异。