Suppr超能文献

[传入乳头瓣功能障碍作为Kock可控回肠储袋的晚期并发症]

[Afferent nipple valve malfunction as a late complication of the Kock continent ileal reservoir].

作者信息

Arai Y, Matsuda T, Hida S, Okada Y, Tadeuchi H, Yoshida O, Kihara Y, Moroi S, Shirahase T, Kanamaru H

机构信息

Department of Urology, Faculty of Medicine, Kyoto University.

出版信息

Hinyokika Kiyo. 1990 Oct;36(10):1155-61.

PMID:2148251
Abstract

Construction of a continent ileal urinary reservoir (Kock pouch) is associated with a high incidence of late complication because of malfunction of the nipple valve, the efferent limb in particular. We have so far experienced several types of afferent nipple malfunction. We herein report on the unexpected complications of the afferent nipple valve in patients with a post operative observation of 1 year or more. From 1984 through 1989, urinary diversion via a Kock pouch was performed on 47 patients at Kyoto University Hospital and Public Toyooka Hospital. The study group comprises 42 patients with a mean observation of 40 months (range 14 to 60 months). The late complications of the afferent nipple valve were observed in 11 of the 42 (26%) patients. These included erosion of Dacron fabric used as a collar (5 patients), afferent nipple stenosis (3 patients) and afferent nipple obstruction by mucous plug or fungus ball (3 patients). Removal of Dacron collar was performed in 4 of the 5 patients with collar erosion and in 1 of the 3 patients with nipple stenosis. Nipple obstruction was relieved by endoscopic manipulation or diuresis. All of the 11 patients had no problems with their efferent nipples. Our results suggest that the use of nonabsorbable material as a collar and peristaltic direction of the afferent limb are mainly involved in the complications of the afferent nipple. A more reliable and simpler procedure for antireflux anastomosis should be considered.

摘要

构建大陆回肠膀胱贮尿囊(Kock 袋)与晚期并发症的高发生率相关,这是由于乳头瓣功能异常,尤其是传出支功能异常所致。到目前为止,我们已经经历了几种类型的传入乳头功能异常。在此,我们报告对术后观察 1 年或更长时间的患者传入乳头瓣出现的意外并发症。1984 年至 1989 年期间,京都大学医院和丰冈市立医院对 47 例患者进行了经 Kock 袋的尿流改道术。研究组包括 42 例患者,平均观察时间为 40 个月(范围 14 至 60 个月)。42 例患者中有 11 例(26%)观察到传入乳头瓣的晚期并发症。这些并发症包括用作套环的涤纶织物侵蚀(5 例)、传入乳头狭窄(3 例)以及黏液栓或真菌球导致的传入乳头梗阻(3 例)。5 例套环侵蚀患者中有 4 例以及 3 例乳头狭窄患者中有 1 例进行了涤纶套环切除。通过内镜操作或利尿缓解了乳头梗阻。所有 11 例患者的传出乳头均无问题。我们的结果表明,使用不可吸收材料作为套环以及传入支的蠕动方向是传入乳头并发症的主要原因。应考虑一种更可靠、更简单的抗反流吻合手术方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验