Abstract

Dual mobility sockets have been introduced in recent years to manage cases of potential instability after hip arthroplasty, and their use is increasing in revision surgery. We present 3 cases of intra-prosthetic dissociation between the outer polyethylene liner and the femoral head after closed reduction of prosthetic dislocation.

摘要

近年来,双动髋臼杯已被引入以处理髋关节置换术后潜在不稳定的病例,并且其在翻修手术中的使用正在增加。我们报告了3例人工关节脱位闭合复位后人工关节内聚乙烯内衬与股骨头之间分离的病例。