BACKGROUND

Total hip arthroplasty is a successful operation for the treatment of hip pain. One of the common complications of hip arthroplasty is dislocation. While reduction of standard prosthetic dislocations is highly successful, new prostheses add the potential for new complications.

CASE REPORT

We present the case of a patient who experienced intraprosthetic dislocation of an anatomic dual-mobility total hip prosthesis after a closed hip reduction and include the prereduction and postreduction radiographic findings.

CONCLUSION

Emergency department physicians should be aware of intraprosthetic dislocation. This complication can be easily missed because the metal/ceramic femoral head appears to be reduced in the acetabulum.

摘要

背景

全髋关节置换术是治疗髋关节疼痛的一种成功手术。髋关节置换术的常见并发症之一是脱位。虽然标准假体脱位的复位成功率很高,但新型假体增加了出现新并发症的可能性。

病例报告

我们报告了一例患者,其在髋关节闭合复位后发生了解剖型双动全髋关节假体的假体内部脱位,并包括复位前后的影像学表现。

结论

急诊科医生应意识到假体内部脱位。这种并发症很容易被漏诊,因为金属/陶瓷股骨头在髋臼内看似已复位。

相似文献

3
Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.双动聚乙烯组件的分离与盆腔内卡压
Clin Orthop Relat Res. 2016 Apr;474(4):1072-6. doi: 10.1007/s11999-015-4381-z. Epub 2015 Jun 19.
5
Intraprosthetic dislocation of dual-mobility total hip arthroplasty implant.双动全髋关节置换植入物的假体内部脱位
Radiol Case Rep. 2023 Aug 30;18(11):3964-3967. doi: 10.1016/j.radcr.2023.08.070. eCollection 2023 Nov.

引用本文的文献

3
Intraprosthetic dislocation of dual-mobility total hip arthroplasty implant.双动全髋关节置换植入物的假体内部脱位
Radiol Case Rep. 2023 Aug 30;18(11):3964-3967. doi: 10.1016/j.radcr.2023.08.070. eCollection 2023 Nov.

本文引用的文献

5
Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.双动聚乙烯组件的分离与盆腔内卡压
Clin Orthop Relat Res. 2016 Apr;474(4):1072-6. doi: 10.1007/s11999-015-4381-z. Epub 2015 Jun 19.
6
Dual mobility cups in total hip arthroplasty.全髋关节置换术中的双动杯
World J Orthop. 2014 Jul 18;5(3):180-7. doi: 10.5312/wjo.v5.i3.180.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验