Suppr超能文献

全髋关节置换术后双下肢长度差异的测量。与 CT 扫描相比,普通 X 线片方法的可靠性。

Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram.

机构信息

Department of Orthopaedics, Sundsvall Hospital, Sundsvall, Sweden.

出版信息

Skeletal Radiol. 2012 Feb;41(2):187-91. doi: 10.1007/s00256-011-1166-7. Epub 2011 Apr 14.

Abstract

OBJECTIVE

To measure the interobserver reliability and intraobserver reproducibility of post total hip arthroplasty (THA) leg length discrepancy (LLD) measurement on radiographs as well as to evaluate its accuracy by comparing it with LLD measurement on computed tomographic scanogram (CT-scanogram).

MATERIALS AND METHODS

In this prospective study, postoperative LLD measurements in ten THA patients were made by four observers on anteroposterior radiographs of the pelvis (inter-teardrop line to the tip of lesser trochanter) and compared to LLD measurements made on CT-scanogram scout views of the lower limb. Two observers repeated the LLD measurements on radiographs 8 weeks after the first measurements. The interobserver reliability of the LLD measurement on plain radiographs was evaluated by comparing the measurements of the four observers and the intraobserver reproducibility by comparing the two repeated measurements made by the two observers.

RESULTS

We found excellent interobserver reliability (mean ICC 0.83) and intraobserver reproducibility (ICC 0.90 and 0.88) of the LLD measurements on plain radiographs. There was a moderate to excellent agreement, but with wide variation of measurements among the four observers, when plain radiographic measurement was compared with CT-scanogram (ICC 0.58, 0.60, 0.71, and 0.82).

CONCLUSION

Despite the excellent interobserver reliability and intraobserver reproducibility of LLD measurement on radiographs, clinicians should be aware of its limited accuracy when compared to CT-scanogram.

摘要

目的

测量全髋关节置换术(THA)后放射影像上肢体长度差异(LLD)测量的观察者间可靠性和观察者内可重复性,并通过与 CT 扫描图(CT-scanogram)上的 LLD 测量比较来评估其准确性。

材料与方法

在这项前瞻性研究中,四位观察者在骨盆前后位 X 线片(泪滴线至小转子尖端)上测量了十名 THA 患者的术后 LLD,并与 CT 扫描图下肢初步视图上的 LLD 测量进行了比较。两位观察者在第一次测量后 8 周时重复了 X 线片上的 LLD 测量。通过比较四位观察者的测量值评估了 X 线片上 LLD 测量的观察者间可靠性,通过比较两位观察者的两次重复测量评估了观察者内可重复性。

结果

我们发现 X 线片上 LLD 测量具有极好的观察者间可靠性(平均 ICC 0.83)和观察者内可重复性(ICC 0.90 和 0.88)。尽管 X 线片测量与 CT 扫描图之间存在中度至极好的一致性,但观察者之间的测量值存在很大差异(ICC 0.58、0.60、0.71 和 0.82)。

结论

尽管 X 线片上 LLD 测量具有极好的观察者间可靠性和观察者内可重复性,但与 CT 扫描图相比,其准确性有限,临床医生应注意这一点。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验