Masters Programme in Physical Therapy, Universidade Federal de Pernambuco, Brazil.
Physiotherapy. 2011 Jun;97(2):100-6. doi: 10.1016/j.physio.2010.08.004. Epub 2010 Oct 23.
Measurements from pressure biofeedback units (PBUs) can be used to evaluate the activity of the transversus abdominis (TrA) muscle indirectly. These measurements can classify patients or monitor the progress of treatment programmes for people with low back pain.
To systematically review studies on the measurement properties of PBUs for the assessment of TrA activity.
Eligible studies were identified through searches of PUBMED, CINAHL and BIREME (1990 to 2009). In addition, hand searches of journals and citation tracking were performed.
Full-text studies involving any type of clinimetric tests of PBU measurement for the assessment of TrA activity were selected.
Two independent reviewers selected the studies, extracted the data and assessed methodological quality.
Due to the heterogeneity of study designs and statistical analysis, it was not possible to pool the data for a meta-analysis.
Six studies met the inclusion criteria. These studies were typically of low quality and recruited healthy subjects rather than patients with low back pain. The studies found moderate to good reproducibility (intra-class correlation coefficients from 0.47 to 0.82) and acceptable construct validity (intra-class correlation coefficients from 0.48 to 0.90).
The current evidence about the measurement properties of PBUs for the assessment of TrA activity is mainly based on studies with suboptimal designs, and the findings from these studies are likely to be overly optimistic. The most important clinical questions about the measurement properties of PBUs for the assessment of TrA activity are yet to be answered.
压力生物反馈单元 (PBU) 的测量结果可用于间接评估腹横肌 (TrA) 的活动。这些测量结果可用于对腰痛患者进行分类或监测治疗计划的进展。
系统评价用于评估 TrA 活动的 PBU 测量性能的研究。
通过检索 PUBMED、CINAHL 和 BIREME(1990 年至 2009 年)确定了符合条件的研究。此外,还对手头的期刊和引文跟踪进行了搜索。
选择了涉及 PBU 测量 TrA 活动评估的任何类型临床计量学测试的全文研究。
两名独立的审查员选择了研究,提取了数据并评估了方法学质量。
由于研究设计和统计分析的异质性,无法对数据进行荟萃分析。
有 6 项研究符合纳入标准。这些研究通常质量较低,且招募的是健康受试者,而非腰痛患者。研究发现中等至良好的可重复性(组内相关系数为 0.47 至 0.82)和可接受的结构有效性(组内相关系数为 0.48 至 0.90)。
目前关于 PBU 评估 TrA 活动的测量性能的证据主要基于设计不太理想的研究,这些研究的结果可能过于乐观。评估 PBU 评估 TrA 活动的测量性能的最重要的临床问题仍有待回答。