Suppr超能文献

短柄髋关节置换术后疲劳骨折:电子显微镜失效分析及文献回顾。

Fatigue fracture of a short stem hip replacement: a failure analysis with electron microscopy and review of the literature.

机构信息

Clinic and Policlinic for Orthopaedic Surgery, University Hospital Giessen and Marburg GmbH, Giessen, Germany.

出版信息

J Arthroplasty. 2011 Jun;26(4):665.e17-20. doi: 10.1016/j.arth.2010.05.021. Epub 2011 Apr 16.

Abstract

Four years after primary implantation of an ESKA Cut short-stemmed prosthesis, a 61-year-old patient suffered fracture of the implant. The combination of missing proximal support of the prosthesis as well as enormous strain on the distal third of the stem can be considered as main reason for the fatigue failure. The special design of the modular implant with a small diameter and a spongy metal surface can be regarded as a contributing factor. This unique case demonstrates a possible failure mechanism of short- and ultra short-stemmed prostheses.

摘要

在初次植入 ESKA 短柄假体四年后,一位 61 岁的患者遭遇了假体骨折。假体近端支撑缺失以及柄的远端三分之一承受巨大压力,这被认为是导致疲劳失效的主要原因。具有小直径和海绵金属表面的模块化假体的特殊设计可以被认为是一个促成因素。这个独特的病例展示了短柄和超短柄假体的一种可能的失效机制。