Kaynak-Türkmen Münevver, Aydoğdu S Ayvaz, Gökbulut Cengiz, Yenisey Ciğdem, Söz Omer, Cetinkaya-Cakmak Bilin
Department of Pediatrics, Faculty of Medicine, Adnan Menderes University, Aydin, Turkey.
Turk J Pediatr. 2011 Jan-Feb;53(1):67-74.
Routine use of transcutaneous bilirubin (TcB) measurement in the newborn nursery could reduce costs, readmission rates for hyperbilirubinemia and the need for total serum bilirubin (TSB) measurements. The aim of this study was to examine the correlation between TcB measurement, as performed using BiliCheck, and TSB, measured with high-pressure liquid chromatography (HPLC) and with standard laboratory methods, and to determine the TcB cutoff points with desirable sensitivity and specificity values for various clinically relevant TSB levels by HPLC. Fifty-four infants of > or = 30 weeks of gestational age were enrolled in the study. Near simultaneous blood collection for TSB analysis by three methods--bedside bilirubinometer, diazo method and HPLC--and TcB measurement were performed. There was good correlation between TcB and HPLC-bilirubin (B) (r = 0.85), TSB by bilirubinometer and HPLC-B (r = 0.91) and TSB by diazo method and HPLC-B (r = 0.91). The cut-off limits providing a sensitivity of 100% for TcB measurements were TcB > or = 9 mg/dl for HPLC-B > 17 mg/dl and TcB > or = 8 mg/dl for HPLC-B > 15 mg/dl and HPLC-B > 13 mg/dl. Despite having good correlation with HPLC, BiliCheck showed worse performance than bilirubinometer and diazo method at various clinically relevant cut-off values. Since BiliCheck required relatively lower thresholds with false-positive results for having a sensitivity of 100%, it cannot be recommended as a complete substitute for serum bilirubin measurements.
在新生儿重症监护室常规使用经皮胆红素(TcB)测量可降低成本、高胆红素血症的再入院率以及总血清胆红素(TSB)测量的需求。本研究的目的是检查使用BiliCheck进行的TcB测量与采用高压液相色谱法(HPLC)和标准实验室方法测量的TSB之间的相关性,并通过HPLC确定针对各种临床相关TSB水平具有理想灵敏度和特异性值的TcB临界值。54名胎龄≥30周的婴儿被纳入研究。通过三种方法(床边胆红素计、重氮法和HPLC)近乎同时采集血样进行TSB分析,并进行TcB测量。TcB与HPLC胆红素(B)之间存在良好相关性(r = 0.85),胆红素计测量的TSB与HPLC - B之间(r = 0.91)以及重氮法测量的TSB与HPLC - B之间(r = 0.91)。对于HPLC - B>17mg/dl,TcB测量灵敏度为100%的临界限值为TcB≥9mg/dl;对于HPLC - B>15mg/dl和HPLC - B>13mg/dl,临界限值为TcB≥8mg/dl。尽管与HPLC具有良好相关性,但在各种临床相关临界值时,BiliCheck的表现比胆红素计和重氮法差。由于BiliCheck为达到100%的灵敏度需要相对较低的阈值且假阳性结果较多,因此不建议将其作为血清胆红素测量的完全替代方法。