Bailly P, Dhondt J L, Drouard L, Houlbert C, Soubiran P, Szymanowicz A
Ann Biol Clin (Paris). 2010 Dec;68 Spec No 1:105-10. doi: 10.1684/abc.2011.0548.
The process is described to help to achieve the requirements of the ISO 15189 standard. The precautions to be respected for a correct recording of the request are specified. The criteria for traceability are formalized. A logogram illustrates the propositions of attitude to be followed when occurs nonconformities. Then, we propose guidelines for the treatment of the identification uncertainties of the primary sample. An algorithm is proposed to formalize the process and treat the situations which can be met with an irreplaceable or critical sample.
描述了该过程以帮助满足ISO 15189标准的要求。规定了正确记录请求时应遵循的预防措施。可追溯性标准得到了规范。一个标识说明了出现不符合项时应遵循的态度建议。然后,我们提出了处理原始样品识别不确定性的指南。提出了一种算法来规范该过程并处理可能遇到不可替代或关键样品的情况。