Severin E J, Sanner R D, Doleman B J, Lewis N S
Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125.
Anal Chem. 1998 Apr 1;70(7):1440-3. doi: 10.1021/ac970757h.
Carbon black-chiral polymer composites were used to provide diagnostic differential resistance responses in the presence of enantiomers of chiral gaseous analytes. Vapors of (+)-2-butanol and (-)-2-butanol, (+)-α-pinene and (-)-α-pinene, (+)-epichlorohydrin and (-)-epichlorohydrin, and methyl (+)-2-chloropropionate and methyl (-)-2-chloropropionate were generated and passed over a chemically sensitive carbon black-poly((R)-3-hydroxybutyrate-co-(R)-3-hydroxyvalerate) (77% butyrate) composite resistor. Each enantiomer of a pair produced a distinct relative differential resistance change on the chiral detector, whereas both enantiomers of a set produced identical signals on achiral carbon black-poly(ethylene-co-vinyl acetate) (82% ethylene) detectors.