Abstract

A sampled delayed scheme is proposed to regulate the organic pollution level in anaerobic digestion processes by using off-line COD measurements. The proposed scheme is obtained by combining an error feedback control with a steady state estimator to track constant references and attenuate process load disturbances. The controller performance is tested experimentally for the treatment of tequila vinasses over a period of 68days under different set-point values and several uncertain scenarios which include badly known kinetic parameters and load disturbances. Experimental results show that the COD concentration can be effectively regulated under the influence of set-point changes and high load disturbances by using only a daily off-line COD measurement, which makes the industrial application of the proposed control scheme feasible.

摘要

提出了一种抽样延迟方案,通过使用离线 COD 测量来调节厌氧消化过程中的有机污染水平。该方案通过将误差反馈控制与稳态估计器相结合,以跟踪恒定参考值并衰减过程负载干扰来获得。该控制器的性能在不同设定值和几个不确定场景下(包括未知的动力学参数和负载干扰)下对龙舌兰酒糟粕进行了 68 天的处理实验进行了测试。实验结果表明,通过仅使用每日离线 COD 测量,在设定值变化和高负载干扰的影响下,可以有效地调节 COD 浓度,这使得所提出的控制方案的工业应用成为可能。