Abstract

The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. We investigated the relationship between serum metal ion levels and contact stress on the acetabular component of MoMHRA patients for two functional activities; gait and stair descent. Four subjects with MoMHRA, who had their serum metal ion levels measured, underwent motion analysis followed by CT scanning. Their motion capture data was combined with published hip contact forces and finite element models representing 14% (peak force) and 60% (end of stance) of the gait cycle and 52% (peak force) of stair descent activity were created. The inclination angle of the acetabular component was increased by 10° in 1° intervals and the contact stresses were determined at each interval for each subject. When the inclination angle was altered in such a way as to cause the hip contact force to pass through the edge of the acetabular component edge-loading occurred. Edge-loading increased the contact stress by at least 50%; the maximum increase was 108%. Patients with low serum metal ion levels showed no increase in contact stress at peak force during gait or stair descent. Patients with high serum metal ion levels exhibited edge-loading with an increase to the inclination angle of their acetabular components. The increase in inclination angle that induced edge-loading for these subjects was less than the inter-subject variability in the angle of published hip contact forces. The results of this study suggest that high serum metal ion levels are the result of inclination angle influenced edge-loading but that edge-loading cannot be attributed to inclination angle alone and that an individual's activity patterns can reduce or even override the influence of a steep acetabular component and prevent edge-loading.

摘要

金属对金属髋关节表面置换术后(MoMHRA)出现假性肿瘤(与髋关节相关的软组织肿块)与高血清金属离子水平有关,进而导致高于正常的轴承磨损。我们研究了 MoMHRA 患者两种功能活动(步态和下楼梯)时血清金属离子水平与髋臼部件接触应力之间的关系。四位 MoMHRA 患者的血清金属离子水平进行了测量,随后进行了运动分析和 CT 扫描。他们的运动捕捉数据与发表的髋关节接触力以及代表步态周期 14%(峰值力)和 60%(站立末期)和 52%(峰值力)的楼梯下降活动的有限元模型相结合。以 1°的间隔将髋臼部件的倾斜角度增加 10°,并为每位患者确定了每个间隔的接触应力。当髋臼部件的倾斜角度发生变化以使髋关节接触力通过髋臼部件边缘时,就会发生边缘加载。边缘加载会使接触应力增加至少 50%;最大增加 108%。血清金属离子水平低的患者在步态或下楼梯时,峰值力时接触应力没有增加。血清金属离子水平高的患者表现出边缘加载,其髋臼部件的倾斜角度增加。对于这些患者,导致边缘加载的倾斜角度增加小于已发表髋关节接触力角度的个体间变异性。这项研究的结果表明,高血清金属离子水平是倾斜角度影响边缘加载的结果,但边缘加载不能仅归因于倾斜角度,个体的活动模式可以减少甚至消除陡峭髋臼部件的影响并防止边缘加载。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验