Suppr超能文献

在前交叉韧带重建过程中,张紧装置位置不当对钢缆张力的影响。

The impact of tensioning device mal-positioning on strand tension during anterior cruciate ligament reconstruction.

机构信息

Comparative Orthopaedic Research Surgical Facility, School of Medicine, Flinders University, South Australia, Australia.

出版信息

J Orthop Surg Res. 2011 Jun 28;6:33. doi: 10.1186/1749-799X-6-33.

Abstract

BACKGROUND

In order to confer optimal strength and stiffness to the graft in Anterior Cruciate Ligament (ACL) reconstruction, the maintenance of equal strand tension prior to fixation, is desired; positioning of the tensioning device can significantly affect strand tension This study aimed to determine the effect of tensioning device mal-positioning on individual strand tension in simulated cadaveric ACL reconstructions.

METHODS

Twenty cadaveric specimens, comprising bovine tibia and tendon harvested from sheep, were used to simulate ACL reconstruction with a looped four-strand tendon graft. A proprietary tensioning device was used to tension the graft during tibial component fixation with graft tension recorded using load cells. The effects of the tensioning device at extreme angles, and in various locking states, was evaluated.

RESULTS

Strand tension varied significantly when the tensioning device was held at extreme angles (p < 0.001) or in 'locked' configurations of the tensioning device (p < 0.046). Tendon position also produced significant effects (p < 0.016) on the resultant strand tension.

CONCLUSION

An even distribution of tension among individual graft strands is obtained by maintaining the tensioning device in an unlocked state, aligned with the longitudinal axis of the tibial tunnel. If the maintenance of equal strand tension during tibial fixation of grafts is important, close attention must be paid to positioning of the tensioning device in order to optimize the resultant graft tension and, by implication, the strength and stiffness of the graft and ultimately, surgical outcome.

摘要

背景

为了使前交叉韧带(ACL)重建中的移植物具有最佳的强度和刚度,希望在固定前保持各股线张力相等;张力装置的定位会显著影响股线张力。本研究旨在确定在模拟尸体 ACL 重建中,张力装置定位不当对各股线张力的影响。

方法

使用 20 个来自绵羊的牛胫骨和肌腱的尸体标本,模拟 ACL 重建,使用环形四股肌腱移植物。使用专用的张力装置在胫骨部件固定时对移植物进行张紧,并使用负载细胞记录移植物张力。评估了张力装置在极端角度和各种锁定状态下的效果。

结果

当张力装置处于极端角度(p<0.001)或张力装置处于“锁定”状态(p<0.046)时,股线张力差异显著。肌腱位置对最终股线张力也有显著影响(p<0.016)。

结论

通过将张力装置保持在未锁定状态并与胫骨隧道的纵轴对齐,可以获得各移植物股线之间均匀的张力分布。如果在固定胫骨时保持各股线张力相等很重要,那么必须密切注意张力装置的定位,以优化最终的移植物张力,从而优化移植物的强度和刚度,最终优化手术结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0cfd/3133604/1f458a9e01ba/1749-799X-6-33-1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验