Department of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610.
Singapore Med J. 2011 Jun;52(6):405-9.
This study aimed to analyse the inter-fraction prostate motion and setup error during intensity-modulated radiotherapy for prostate cancer at the National Cancer Centre Singapore.
Gold seeds were implanted as fiducial markers. Daily portal films were taken and displacements of the gold seeds from the isocentre in each axis were recorded. Random and systematic errors were used to derive a margin recipe for each axis based on the van Herk formula.
1,077 fractions from 36 patients were analysed. 89.8 percent, 85.2 percent and 83.6 percent of the setup errors were within +/- 2 mm for the right-left (RL), superior-inferior (SI) and anterior-posterior (AP) axes, respectively. The population systematic errors were 0.71 mm, 0.84 mm and 0.87 mm; the population random errors were 1.32 mm, 1.59 mm and 1.70 mm; the overall population mean setup errors were -0.14 (range -2.27 to 1.15) mm, 0.11 (range -2.32 to 1.69) mm and 0.08 (range -1.33 to 1.46) mm; and the van Herk margin recipes were 2.69 mm, 3.22 mm and 3.37 mm for the RL, SI and AP axes, respectively.
The setup errors and inter-fraction prostate movements were small. Gold seed implantation is a feasible and easy method of verifying the prostate position.
本研究旨在分析新加坡国家癌症中心前列腺癌调强放疗过程中的分次内前列腺运动和摆位误差。
植入金种子作为基准标记物。每天拍摄射野影像,记录金种子在各轴线上相对于等中心点的位移。根据范·赫克公式,使用随机误差和系统误差为每个轴推导一个边缘配方。
分析了 36 名患者的 1077 个分次。89.8%、85.2%和 83.6%的左右(RL)、上下(SI)和前后(AP)轴摆位误差在 +/- 2mm 以内。人群系统误差分别为 0.71mm、0.84mm 和 0.87mm;人群随机误差分别为 1.32mm、1.59mm 和 1.70mm;总体人群平均摆位误差分别为-0.14(范围-2.27 至 1.15)mm、0.11(范围-2.32 至 1.69)mm 和 0.08(范围-1.33 至 1.46)mm;范·赫克边缘配方分别为 2.69mm、3.22mm 和 3.37mm,用于 RL、SI 和 AP 轴。
摆位误差和分次内前列腺运动较小。金种子植入是验证前列腺位置的一种可行且简便的方法。