Tapasztó Beáta, Veres Amarilla, Kosina-Hagyó Krisztina, Somfai Gábor Márk, Németh János
Department of Ophthalmology, Semmelweis University, Budapest, Hungary.
Optom Vis Sci. 2011 Oct;88(10):1206-13. doi: 10.1097/OPX.0b013e3182274e8f.
To visualize, using Fourier-domain optical coherence tomography (FD-OCT), the alterations in lid-parallel conjunctival fold (LIPCOF) morphology in eyes with contact lenses and after their removal.
One randomly selected eye of each of 24 volunteers with normal ocular surface status was examined using FD-OCT. The study group included 18 female and 6 male subjects, with a mean age of 28.9 years (range, 18-50 years). The presence, height, and number of conjunctival folds and the tear meniscus area were evaluated by FD-OCT, and the difference between "before and after lens removal" were analyzed by the Wilcoxon signed-rank test. To determine the coverage of the folds, the OCT-LIPCOF grading system was applied. Visualization of the folds was compared on linear and raster scans. The Spearman rank test was applied for correlations (SPSS 16.0; SPSS Inc., Chicago, MI).
OCT scans were able to visualize and objectively describe the LIPCOF and its relation to the tear film in contact lens wearers. Raster scanning provided more information about the folds, but the measurements were easier to carry out on the single line scans. After removal of the contact lens, the height of the conjunctival folds significantly decreased (p < 0.001), and the tear meniscus area significantly increased (p = 0.017). The number of LIPCOF did not change (p = 0.971), but LIPCOF coverage by the tear film increased after lens' removal and resulted in changes in the OCT-LIPCOF grading (p < 0.001).
FD-OCT could be a quick, non-invasive, quantitative method for the imaging of LIPCOF in contact lens patients. When grading LIPCOF, the mechanical forces of the lens and the tear meniscus changes caused by the lens should be taken into account as these factors influence results. Follow-up of the patients using the same methods is suggested with or without contact lenses.
使用傅里叶域光学相干断层扫描(FD-OCT)观察佩戴隐形眼镜的眼睛及其摘除后睑平行结膜皱襞(LIPCOF)形态的变化。
使用FD-OCT对24名眼表状况正常的志愿者的一只随机选择的眼睛进行检查。研究组包括18名女性和6名男性受试者,平均年龄为28.9岁(范围18 - 50岁)。通过FD-OCT评估结膜皱襞的存在、高度和数量以及泪液半月皱襞面积,并采用Wilcoxon符号秩检验分析“摘除镜片前后”的差异。为确定皱襞的覆盖范围,应用了OCT-LIPCOF分级系统。在线性扫描和光栅扫描上比较皱襞的可视化情况。采用Spearman秩检验进行相关性分析(SPSS 16.0;SPSS公司,芝加哥,密歇根州)。
OCT扫描能够可视化并客观描述隐形眼镜佩戴者的LIPCOF及其与泪膜的关系。光栅扫描提供了更多关于皱襞的信息,但在单一线性扫描上进行测量更容易。摘除隐形眼镜后,结膜皱襞的高度显著降低(p < 0.001),泪液半月皱襞面积显著增加(p = 0.017)。LIPCOF的数量没有变化(p = 0.971),但摘除镜片后泪膜对LIPCOF的覆盖增加,并导致OCT-LIPCOF分级发生变化(p < 0.001)。
FD-OCT可能是一种用于隐形眼镜患者LIPCOF成像的快速、非侵入性定量方法。在对LIPCOF进行分级时,应考虑镜片的机械力以及镜片引起的泪液半月皱襞变化,因为这些因素会影响结果。建议对患者使用相同方法进行随访,无论是否佩戴隐形眼镜。