Stafford G H, Islam S Ul, Witt J D
University College London Hospital, 235 Euston Road, London NW1 2BU, UK.
J Bone Joint Surg Br. 2011 Aug;93(8):1017-20. doi: 10.1302/0301-620X.93B8.26505.
Ceramic-on-ceramic bearings in hip replacement have low rates of wear and are increasingly being used in young adults. Our aim was to determine the incidence of audible phenomena or other bearing-related complications. We retrospectively analysed 250 ceramic-on-ceramic hip replacements in 224 patients which had been implanted between April 2000 and December 2007. The mean age of the patients at operation was 44 years (14 to 83) and all the operations were performed using the same surgical technique at a single centre. At a mean follow-up of 59 months (24 to 94), the mean Oxford hip score was 40.89 (11 to 48). There were six revisions, three of which were for impingement-related complications. No patient reported squeaking, but six described grinding or clicking, which was usually associated with deep flexion. No radiological evidence of osteolysis or migration of the components was observed in any hip. The early to mid-term results of contemporary ceramic-on-ceramic hip replacement show promising results with few concerns in terms of noise and squeaking. Positioning of the acetabular component remains critical in regard to the reduction of other impingement-related complications.
髋关节置换术中的陶瓷对陶瓷轴承磨损率低,越来越多地应用于年轻人。我们的目的是确定可听现象或其他与轴承相关并发症的发生率。我们回顾性分析了2000年4月至2007年12月期间在224例患者中植入的250例陶瓷对陶瓷髋关节置换术。患者手术时的平均年龄为44岁(14至83岁),所有手术均在单一中心采用相同的手术技术进行。平均随访59个月(24至94个月),牛津髋关节平均评分为40.89(11至48)。有6例翻修手术,其中3例是因撞击相关并发症。没有患者报告有吱吱声,但有6例描述了摩擦声或咔嗒声,这通常与深度屈曲有关。在任何髋关节中均未观察到骨溶解或假体部件移位的影像学证据。当代陶瓷对陶瓷髋关节置换术的早期至中期结果显示出令人满意的结果,在噪音和吱吱声方面几乎没有问题。髋臼假体的定位对于减少其他撞击相关并发症仍然至关重要。