采用血细胞流动分析法对白细胞减少样本的白细胞分类进行可靠、准确的测定。

Reliable, accurate determination of the leukocyte differential of leukopenic samples by using Hematoflow method.

作者信息

Jo Yongjun, Kim Soo Hwa, Koh Kwangsang, Park Jongmoon, Shim Yang Bo, Lim Jihyang, Kim Yonggoo, Park Yeon-Joon, Han Kyungja

机构信息

Department of Laboratory Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea.

出版信息

Korean J Lab Med. 2011 Jul;31(3):131-7. doi: 10.3343/kjlm.2011.31.3.131. Epub 2011 Jun 28.

Abstract

BACKGROUND

Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method.

METHODS

We selected 249 blood samples from 167 patients with leukopenia (WBC counts, 500-2,000/µL) for analysis in this study. The EDTA-anticoagulated blood samples were analyzed using an automatic blood cell counter (DxH800; Beckman Coulter, USA) and flow cytometry (FC 500; Beckman Coulter) by using Cytodiff reagent and analysis software (Beckman Coulter). Hematoflow results were selected or calculated from DxH800 and Cytodiff results. Two trained pathologists performed a manual differential count by counting 50-100 cells.

RESULTS

The precision of the Hematoflow method was superior to that of the manual method in counting 5 leukocyte subpopulations, immature granulocytes (IGs), and blasts. Blasts were detected in all 45 cases (100%) by Hematoflow. The correlation of the Cytodiff blast count to the reference count was high (r = 0.8325). For all other cell populations, the correlation of the Hematoflow results with the reference count was stronger than that of the other manual counts with the reference count.

CONCLUSIONS

The Hematoflow differential counting method is more reproducible and sensitive than manual counting, and is relatively easy to perform. In particular, this method detected leukemic blasts more sensitively than manual differential counts. The Hematoflow method is a very useful supplement to automated cell counting.

摘要

背景

血液分析仪可能无法有效识别异常细胞,而对于白细胞减少的样本,手工分类计数可能不准确。我们评估了血细胞流式分析法在确定白细胞减少样本中白细胞分类的有效性,并将该方法与手工分类法进行了比较。

方法

我们从167例白细胞减少症患者(白细胞计数为500 - 2000/µL)中选取了249份血样进行本研究分析。使用自动血细胞计数器(DxH800;美国贝克曼库尔特公司)和流式细胞仪(FC 500;贝克曼库尔特公司),通过使用细胞分类试剂和分析软件(贝克曼库尔特公司)对乙二胺四乙酸抗凝的血样进行分析。血细胞流式分析结果从DxH800和细胞分类结果中选取或计算得出。两名经过培训的病理学家通过计数50 - 100个细胞进行手工分类计数。

结果

在计数5种白细胞亚群、未成熟粒细胞(IGs)和原始细胞时,血细胞流式分析法的精密度优于手工方法。血细胞流式分析法在所有45例病例(100%)中均检测到了原始细胞。细胞分类原始细胞计数与参考计数的相关性较高(r = 0.8325)。对于所有其他细胞群体,血细胞流式分析结果与参考计数的相关性强于其他手工计数与参考计数的相关性。

结论

血细胞流式分类计数法比手工计数更具可重复性和敏感性,且操作相对简便。特别是,该方法比手工分类计数更能灵敏地检测到白血病原始细胞。血细胞流式分析法是自动细胞计数的一种非常有用的补充方法。