Suppr超能文献

CT血管造影术在评估 Willis 环中的准确性:容积再现图像与数字减影血管造影术的比较

Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography.

作者信息

Han Ari, Yoon Dae Young, Chang Suk Ki, Lim Kyoung Ja, Cho Byung-Moon, Shin Yoon Cheol, Kim Sam Soo, Kim Keon Ha

机构信息

Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, Seoul, Republic of Korea.

出版信息

Acta Radiol. 2011 Oct 1;52(8):889-93. doi: 10.1258/ar.2011.110223. Epub 2011 Jul 29.

Abstract

BACKGROUND

Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases.

PURPOSE

To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis.

MATERIAL AND METHODS

One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-com A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CTA volume-rendered images. The CTA results were then compared with findings on the corresponding DSA images (reference standard).

RESULTS

The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CTA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%.

CONCLUSION

CTA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments.

摘要

背景

计算机断层血管造影(CTA)越来越多地用于脑血管疾病的无创成像。

目的

评估CTA在评估 Willis 环各节段管径变异方面的准确性。

材料与方法

回顾性评估117例急性蛛网膜下腔出血患者(51例男性,66例女性,平均年龄50.9岁),这些患者均接受了16排CT扫描仪的CTA检查及数字减影血管造影(DSA)检查。CTA和DSA检查在症状发作后24小时内且彼此间隔24小时内进行。由不知情的观察者通过评估CTA容积再现图像,将 Willis 环的总共819个动脉节段(前交通动脉、左右A1段、左右后交通动脉以及左右P1段)判定为发育不全(1级)、发育不良(2级)或正常大小(3级)。然后将CTA结果与相应DSA图像(参考标准)的结果进行比较。

结果

CTA与DSA之间的总体一致性为92.4%。两种检查方式之间有62例(7.6%)不一致情况(CTA低估58例,高估4例)。CTA检测发育不全和正常大小节段的敏感性和特异性均超过90%。相比之下,发育不良节段的亚组分析显示敏感性为52.6%,特异性为98.2%。

结论

CTA在评估 Willis 环的解剖变异方面具有高度准确性;然而,其在描绘发育不良节段方面的敏感性有限。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验