Suppr超能文献

辅助纤维桩对根管口敞开的牙的影响。

Effects of auxiliary fiber posts on endodontically treated teeth with flared canals.

机构信息

School and Hospital of Stomatology, Wuhan University, Wuhan, China

出版信息

Oper Dent. 2011 Jul-Aug;36(4):380-9. doi: 10.2341/10-283-L. Epub 2011 Aug 11.

Abstract

This study investigated the fracture resistance and retention of endodontically treated roots with over-flared canals restored with different post systems, including one cast metal post and four fiber posts with/without auxiliary fiber posts. One hundred endodontically treated incisor roots were experimentally flared using a tapered diamond bur. The roots were restored using one of the five post systems: Ni-Cr cast metal post (CM), D.T. Light glass fiber post (DT), Macro-Lock glass fiber post (ML), ML+2 Fibercone auxiliary fiber posts (2FC), and ML+5 Fibercone auxiliary fiber posts (5FC). After fabrication of the crowns, half of the specimens (n=50) were subjected to a fracture failure test--loading with an incremental static force at an angle of 45 degrees to the long axis of the root. The other 50 samples underwent a pull-out test. Fracture failure strength and pull-out strength were measured and analyzed using one-way analysis of variance (ANOVA) followed by Tukey's post hoc test (α=0.05). After the tests were completed, all specimens displayed oblique root fractures or cracks, initiating from the palatal cervical margin and propagating in a labial-apical direction. The order of the fracture failure strength was as follows: 5FC=CM=2FC>ML>DT. Cast metal posts demonstrated the highest pull-out strength (p<0.05). No significant differences in pull-out strength were found in the ML, 2FC, and 5FC groups. Within the limitations of this study, it was concluded that the application of an auxiliary fiber post could significantly increase the fracture resistance of over-flared roots; however, no beneficial effects in enhancing retention were observed.

摘要

本研究旨在探讨不同桩核系统修复超扩根管的抗折强度和固位力,包括 1 种铸造金属桩和 4 种纤维桩(有/无辅助纤维桩)。采用锥形金刚石车针对 100 颗牙髓病治疗后的切牙进行根管超扩。然后采用 5 种桩核系统之一修复这些根管:镍铬铸造金属桩(CM)、D.T. Light 玻璃纤维桩(DT)、Macro-Lock 玻璃纤维桩(ML)、ML+2 Fibercone 辅助纤维桩(2FC)和 ML+5 Fibercone 辅助纤维桩(5FC)。制备完牙冠后,将一半标本(n=50)进行断裂失效测试——以 45 度角向根的长轴方向施加递增静载。另一半 50 个样本进行拔出测试。采用单因素方差分析(ANOVA),然后进行 Tukey 事后检验(α=0.05),对断裂失效强度和拔出强度进行测量和分析。测试完成后,所有标本均显示斜向根折或裂缝,起始于腭侧颈缘,向唇侧-根尖方向扩展。断裂失效强度的顺序如下:5FC=CM=2FC>ML>DT。铸造金属桩的拔出强度最高(p<0.05)。在 ML、2FC 和 5FC 组之间,拔出强度无显著差异。在本研究的限制范围内,可以得出结论,应用辅助纤维桩可以显著提高超扩根管的抗折强度;然而,在增强固位力方面没有观察到有益效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验