Suppr超能文献

根管治疗后前磨牙全瓷冠修复下氧化锆桩、铸造镍铬合金桩及玻璃纤维复合桩的抗折性能

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars.

作者信息

Habibzadeh Sareh, Rajati Hamid Reza, Hajmiragha Habib, Esmailzadeh Shima, Kharazifard Mohamadjavad

机构信息

Department of Prosthodontics, Tehran University of Medical Sciences, International Campus, School of Dentistry, Tehran, Iran.

Department of Prosthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.

出版信息

J Adv Prosthodont. 2017 Jun;9(3):170-175. doi: 10.4047/jap.2017.9.3.170. Epub 2017 Jun 19.

Abstract

PURPOSE

The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars.

MATERIALS AND METHODS

A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (α=.05).

RESULTS

Fiber-glass posts with composite cores showed the highest fracture resistance values (915.70±323 N), and the zirconia post system showed the lowest resistance (435.34±220 N). The corresponding mean value for the Ni-Cr casting post and cores was reported as 780.59±270 N. The differences among the groups were statistically significant (<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests.

CONCLUSION

The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiberglass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

摘要

目的

本研究旨在评估在根管治疗后的下颌第一前磨牙上,全瓷冠修复下氧化锆、铸造镍铬合金(Ni-Cr)和纤维复合桩系统的抗折强度。

材料与方法

共选取36颗拔除的人下颌前磨牙,进行标准根管治疗,然后分为三组(n = 12),如下:铸造Ni-Cr桩核、一体式定制铣削氧化锆桩核、以及带有复合树脂核的预制玻璃纤维桩。每个样本均有一个带有氧化锆基底冠的全瓷冠,然后使用万能试验机以0.5 mm/min的十字头速度、与牙根长轴呈45度角加载直至破坏。分析抗折强度和破坏模式。使用方差分析(ANOVA)和Tukey诚实显著性差异(HSD)检验(α = 0.05)评估结果的显著性。

结果

带有复合核的玻璃纤维桩显示出最高的抗折强度值(915.70±323 N),氧化锆桩系统显示出最低的抗折强度(435.34±220 N)。Ni-Cr铸造桩核的相应平均值报告为780.59±270 N。经ANOVA和Tukey HSD检验,氧化锆组各分组间差异具有统计学意义(P<0.05)。

结论

发现氧化锆桩核系统的抗折强度显著低于玻璃纤维桩和铸造Ni-Cr桩系统。此外,氧化锆桩修复的牙齿中灾难性和不可修复性骨折更为普遍。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aeaa/5483402/39e80f9b9d0c/jap-9-170-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验