Gagała Jacek, Mazurkiewicz Tomasz, Dajewski Zbigniew
Katedra i Klinika Ortopedii i Traumatologii, Uniwersytet Medyczny w Lublinie.
Chir Narzadow Ruchu Ortop Pol. 2011 Jan-Feb;76(1):14-20.
The aim of the study was a preliminary report of the use of large diameter alumina femoral heads in total hip arthroplasty.
In the years 2005-2008 50 THRs were implanted in 48 patients with the use of 36 mm alumina femoral heads. 5 women and 43 men in the age from 35 to 75 years (average 61 years) were operated on. Primary osteoarthritis was the cause of 41 arthroplasties, and AVN of femoral head of 9 surgeries. 18 alumina/alumina and 32 polyethylene/alumina THRs were implanted. The prospective study consisted of clinical examination with Harris Hip Score and X-ray evaluation. AP and lateral view X-rays were evaluated. The incidence of radiolucent lines around acetabular cups were noted with DeLee and Charnley zones and around stems with Gruen's zones.
The follow up is from 24 to 58 months (average 40 months). There was an increase in Harris Hip Score from average 37 points (from 25 to 49 points) before operation to average 94 points (from 90 to 100 points) after the surgery. The incidence of postoperative dislocation have not been noted. Long-term postoperative X-ray examination have showed proper geometry of endoprostheses without radiolucent lines. Neither visible wear of bearing surfaces nor breakage of alumina components have been noted.
本研究旨在初步报告大直径氧化铝股骨头在全髋关节置换术中的应用情况。
在2005年至2008年期间,对48例患者植入了50个全髋关节置换假体,使用的是36毫米氧化铝股骨头。接受手术的患者中,有5名女性和43名男性,年龄在35岁至75岁之间(平均61岁)。41例置换手术的病因是原发性骨关节炎,9例手术的病因是股骨头缺血性坏死。植入了18个氧化铝/氧化铝和32个聚乙烯/氧化铝全髋关节置换假体。前瞻性研究包括采用Harris髋关节评分进行临床检查以及X线评估。对前后位和侧位X线片进行了评估。记录了髋臼杯周围按照DeLee和Charnley分区以及股骨柄周围按照Gruen分区的透亮线发生率。
随访时间为24至58个月(平均40个月)。Harris髋关节评分从术前平均37分(25分至49分)增加到术后平均94分(90分至100分)。未发现术后脱位情况。长期术后X线检查显示假体几何形状正常,无透亮线。未发现承重面有明显磨损,也未发现氧化铝部件断裂。
1)在全髋关节置换术中使用36毫米股骨头可降低术后脱位风险。2)创新生物材料:氧化铝陶瓷和交联聚乙烯有望降低骨溶解的发生率。