Department of Bioengineering, University of Utah, Salt Lake City, UT 84112, USA.
IEEE Trans Neural Syst Rehabil Eng. 2011 Oct;19(5):483-9. doi: 10.1109/TNSRE.2011.2162635. Epub 2011 Aug 22.
Trans-radial amputee subjects were implanted with intrafascicular electrodes in the stumps of the median and ulnar nerves. Electrical stimulation through these electrodes was used to provide sensations of touch and finger position referred to the amputated hand. Two subjects were asked to identify different objects as to size and stiffness by manipulating them with a myo-electric hand without visual or auditory cues. Both subjects were provided with information about contact force with the objects via tactile sensations referred to their phantom hands. One subject, who was provided with information about finger position in the prosthetic hand via a different tactile sensation referred to his phantom hand, was unable to correctly identify the objects. The other subject, who received information about finger position via a proprioceptive sensation referred to his phantom hand, correctly identified the objects at a level statistically significantly above chance performance.
经桡骨截肢患者的残肢中植入了神经内电极,分别位于正中神经和尺神经的残端。通过这些电极进行电刺激,为截肢手提供触觉和手指位置的感觉。两名患者在没有视觉或听觉提示的情况下,使用肌电手操纵不同的物体,以识别它们的大小和硬度。通过触及残肢手的感觉,为两名患者提供了关于与物体接触力的信息。其中一名患者通过触及残肢手的另一种感觉来获得关于假肢手手指位置的信息,但无法正确识别物体。另一名患者通过触及残肢手的本体感觉来获得关于手指位置的信息,他能够正确识别物体,其表现明显高于随机水平。