Suppr超能文献

虹膜固定型有晶状体眼人工晶状体对视网膜杂散光的影响。

The effect of iris-fixated foldable phakic intraocular lenses on retinal straylight.

机构信息

University Eye Clinic Maastricht, University Hospital Maastricht, The Netherlands.

出版信息

Am J Ophthalmol. 2011 Dec;152(6):969-975.e2. doi: 10.1016/j.ajo.2011.05.024. Epub 2011 Aug 25.

Abstract

PURPOSE

To determine changes in straylight after iris-fixated phakic intraocular lens implantation (pIOL) and to investigate the relationship between straylight and several preoperative and postoperative variables.

DESIGN

Institutional, prospective cross-sectional study.

METHODS

Artiflex (Ophtec B.V.) pIOL implantation was performed in 61 eyes (36 patients). Straylight values were measured before surgery and 3 months after surgery using the Oculus C-Quant (Oculus Optikgeräte). Furthermore, correlations were analyzed between straylight and the following parameters: keratometry, axial length, spherical equivalent, astigmatism, pIOL power, best spectacle-corrected visual acuity, and pupil size.

RESULTS

Mean straylight decreased from 1.18 ± 0.17 log units before surgery to 1.13 ± 0.17 after surgery (P = .016). Higher preoperative straylight values were associated with larger postoperative decreases in straylight (r = -0.534; P < .001). Higher postoperative straylight values were correlated to higher axial length (r = 0.444; P = .001) and lower keratometry values in diopters (r = -0.414; P = .001). After regression analysis, only axial length was found to be an independent predictor of preoperative and postoperative straylight (P < .001 and P = .001, respectively). After correcting for the axial length of an emmetropic eye (23.44 mm), all straylight correlations disappeared, indicating that an increase in distance from cornea to retina explains the increase in straylight values in longer eyes.

CONCLUSIONS

Retinal straylight was reduced significantly after Artiflex pIOL implantation. Besides age, axial length was the only predictor of preoperative and postoperative straylight values. The increased tissue length light has to pass from cornea to retina, might explain the increase in straylight values in longer eyes.

摘要

目的

确定虹膜固定型有晶状体眼人工晶状体(pIOL)植入术后散射光的变化,并研究散射光与术前和术后多个变量之间的关系。

设计

机构前瞻性横断面研究。

方法

在 61 只眼(36 例患者)中进行了 Artiflex(Ophtec B.V.)pIOL 植入。使用 Oculus C-Quant(Oculus Optikgeräte)在术前和术后 3 个月测量散射光值。此外,还分析了散射光与以下参数之间的相关性:角膜曲率计、眼轴长度、等效球镜、散光、pIOL 功率、最佳矫正视力和瞳孔大小。

结果

平均散射光从术前的 1.18 ± 0.17 log 单位降低至术后的 1.13 ± 0.17(P =.016)。术前散射光值较高与术后散射光值下降较大相关(r = -0.534;P <.001)。术后散射光值较高与眼轴长度较高(r = 0.444;P =.001)和较低的屈光度角膜曲率值(r = -0.414;P =.001)相关。回归分析后,仅眼轴长度被发现是术前和术后散射光的独立预测因子(P <.001 和 P =.001)。在矫正正视眼的眼轴长度(23.44mm)后,所有散射光相关性均消失,表明从角膜到视网膜的距离增加解释了较长眼的散射光值增加。

结论

Artiflex pIOL 植入术后视网膜散射光显著降低。除年龄外,眼轴长度是术前和术后散射光值的唯一预测因子。从角膜到视网膜的组织长度增加,可能解释了较长眼散射光值的增加。