短时间评估可植入 Collamer 透镜植入术后矫正高度近视的眼内散射。

Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia.

机构信息

Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, No. 4 Gansu Road, Heping District, Tianjin, People's Republic of China.

出版信息

BMC Ophthalmol. 2020 Jun 17;20(1):235. doi: 10.1186/s12886-020-01482-1.

Abstract

BACKGROUND

To compare the intraocular scattering before and after implantation of implantable collamer lens (ICL) V4c for correction of high myopia in a short term.

METHODS

In this study, 38 eyes of 19 patients who underwent the implantation of ICL V4c were followed up for 3 months. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), objective scattering index (OSI), modulation transfer function cutoff frequency (MTF cutoff), strehl ratio (S/R), OV100%, OV20% and OV9% were measured pre- and postoperatively. Meantime, the Pseudophakic Dysphotopsia Questionnaire (PDQ) was scored to evaluate the subjective satisfaction of intraocular scattering pre- and postoperatively.

RESULTS

The UCVA were - 0.02 ± 0.06, - 0.03 ± 0.07 and - 0.04 ± 0.07 logMAR at 1 week, 1 month and 3 months postoperatively which were significantly better than those preoperatively (P < 0.05). The BCVA were - 0.09 ± 0.09, - 0.09 ± 0.1 and - 0.1 ± 0.11 logMAR at 1 week, 1 month and 3 months after surgery, which were better than those before surgery significantly (t = 15.64, P < 0.05). The mean OSI were 2.37 ± 1.6, 1.63 ± 0.94, 1.5 ± 0.86 and 1.43 ± 1.05 preoperatively, 1 week, 1 month and 3 months postoperatively which was found significant difference (F = 12.92 P < 0.05). No significant differences were found in MTF cut off (F = 0.61, P = 0.62), S/R (F = 0.58, P = 0.36), OV100% (F = 0.966, P = 0.65), OV20% (F = 0.121, P = 0.96) and OV9% (F = 1.01, P = 0.30) between pre- and postoperatively. The PDQ results indicated that intraocular scattering reduced at 3 months after surgery significantly (P < 0.05).

CONCLUSIONS

The ICL V4c implantation for correcting high myopia induced less intraocular scattering and visual disorder than spectacle correction.

摘要

背景

比较可植入 Collamer 透镜(ICL V4c)植入矫正高度近视后短期内的眼内散射情况。

方法

本研究对 19 例(38 只眼)接受 ICL V4c 植入的患者进行了 3 个月的随访。分别于术前和术后测量裸眼视力(UCVA)、最佳矫正视力(BCVA)、客观散射指数(OSI)、调制传递函数截止频率(MTF cutoff)、斯特列尔比(S/R)、OV100%、OV20%和 OV9%。同时,使用假性近视性视觉障碍问卷(PDQ)对术前和术后眼内散射的主观满意度进行评分。

结果

术后 1 周、1 个月和 3 个月的 UCVA 分别为-0.02±0.06、-0.03±0.07 和-0.04±0.07 logMAR,均明显优于术前(P<0.05)。术后 1 周、1 个月和 3 个月的 BCVA 分别为-0.09±0.09、-0.09±0.1 和-0.1±0.11 logMAR,均明显优于术前(t=15.64,P<0.05)。术后 1 周、1 个月和 3 个月的平均 OSI 分别为 2.37±1.6、1.63±0.94、1.5±0.86 和 1.43±1.05,术前分别为 1.43±1.05、1 周、1 个月和 3 个月,差异有统计学意义(F=12.92,P<0.05)。MTF cutoff(F=0.61,P=0.62)、S/R(F=0.58,P=0.36)、OV100%(F=0.966,P=0.65)、OV20%(F=0.121,P=0.96)和 OV9%(F=1.01,P=0.30)差异均无统计学意义。PDQ 结果表明,术后 3 个月眼内散射明显减少(P<0.05)。

结论

与眼镜矫正相比,ICL V4c 植入矫正高度近视引起的眼内散射和视觉障碍更少。