Measurement of ulnar variance on uncalibrated digital radiographic images.

作者信息

de Vries Johannes, Souer J Sebastiaan, Zurakowski David, Ring David

出版信息

Hand (N Y). 2010 Sep;5(3):267-72. doi: 10.1007/s11552-009-9249-9. Epub 2009 Dec 22.

Abstract

Uncalibrated digital radiographs used in multicenter trials hinder quantitative measures such as articular step and ulnar variance. This investigation tested the reliability of alternative measures of ulnar variance that are scaled to the length of the capitate. A sample of 30 sets of radiographs from patients enrolled in a prospective study of operative treatment of fractures of the distal radius were blinded and randomized. Five observers measured the ulnar variance (UV) and longitudinal length of the capitate (CH) on two separate occasions with greater than 2 weeks between measurements. During each measurement session, the observers made the measurements on both a calibrated and a noncalibrated workstation. The ratio of the ulnar variance to the length of capitate was calculated (UV/CH ratio). Paired t tests were used to compare two rounds of measurements for both methods. Intra- and interobserver reliability was assessed by the Pearson product-moment correlation coefficients. The ratios were compared using analysis of variance with a Bonferroni correction. The intraobserver reliability was excellent for each of the three variables (UV, CH, UV/CH ratio) for each workstation. The interobserver reliability of the UV/CH ratios obtained for each workstation was moderate to excellent as judged by the Pearson correlations between observers. The Bland-Altman method indicated a mean difference in UV/CH between calibrated and uncalibrated measurement techniques of 0.002 with limits of agreement of -0.11 to 0.11. Measurements of ulnar variance that are scaled to the length of the capitate may be useful measures of deformity in studies that utilize uncalibrated digital radiographs.

摘要

多中心试验中使用的未经校准的数字X线片妨碍了诸如关节台阶和尺骨变异等定量测量。本研究测试了根据头状骨长度进行缩放的尺骨变异替代测量方法的可靠性。对30组来自一项前瞻性桡骨远端骨折手术治疗研究患者的X线片进行了盲法随机分组。五名观察者在两次独立的测量中测量尺骨变异(UV)和头状骨的纵向长度(CH),两次测量间隔超过2周。在每次测量过程中,观察者在经过校准和未经校准的工作站上进行测量。计算尺骨变异与头状骨长度的比值(UV/CH比值)。配对t检验用于比较两种方法的两轮测量结果。观察者内和观察者间的可靠性通过Pearson积矩相关系数进行评估。使用方差分析并进行Bonferroni校正来比较这些比值。每个工作站的三个变量(UV、CH、UV/CH比值)的观察者内可靠性都非常好。根据观察者之间的Pearson相关性判断,每个工作站获得的UV/CH比值的观察者间可靠性为中等至优秀。Bland-Altman方法表明,校准和未校准测量技术之间的UV/CH平均差异为0.002,一致性界限为-0.11至0.11。在使用未经校准数字X线片的研究中,根据头状骨长度进行缩放的尺骨变异测量可能是有用的畸形测量方法。

相似文献

2
Negative Ulnar Variance and Kienböck Disease.尺骨负变异与月骨无菌性坏死
J Hand Surg Am. 2016 Feb;41(2):214-8. doi: 10.1016/j.jhsa.2015.10.014. Epub 2015 Dec 11.

本文引用的文献

1
Prediction of instability in distal radial fractures.桡骨远端骨折不稳定性的预测。
J Bone Joint Surg Am. 2006 Sep;88(9):1944-51. doi: 10.2106/JBJS.D.02520.
4
Changes in ulnar variance in relation to forearm rotation and grip.尺骨变异与前臂旋转及握力的关系变化
J Bone Joint Surg Br. 2001 Sep;83(7):1029-33. doi: 10.1302/0301-620x.83b7.11062.
5
The importance of the pronated grip x-ray view in evaluating ulnar variance.
J Hand Surg Am. 2000 Mar;25(2):352-7. doi: 10.1053/jhsu.2000.jhsu25a0352.
7
X-ray film measurements for healed distal radius fractures.愈合的桡骨远端骨折的X线片测量
J Hand Surg Am. 1996 Jan;21(1):31-9. doi: 10.1016/S0363-5023(96)80151-1.
9
An alternative method for determination of the carpal height ratio.一种测定腕高比的替代方法。
J Bone Joint Surg Am. 1994 Jan;76(1):88-94. doi: 10.2106/00004623-199401000-00011.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验