Harman S M, Danner R L
J Clin Endocrinol Metab. 1977 Nov;45(5):953-9. doi: 10.1210/jcem-45-5-953.
DEAE cellulose "mini" columns at pH 7.4 retain testosterone (T) bound to testosterone binding globulin (TeBG), which can be eluted at pH 2. Small 1:2 diluted serum or plasma samples are incubated with a tracer dose of tritiated T in pH 7.4 Tris buffer at 37 C then chilled and placed on columns at 4 C. Free and albumin bound T are washed off columns with pH 7.4 Tris buffer and columns are eluted with pH 2 Tris into vials for scintillation counting. After a simple mathematical correction for the small residual fraction of albumin bound T eluted at pH 2, we obtain a measure of TeBG binding of T which is highly correlated (r = .945) with that determined by dialysis. The method is quick, reproducible and applicable to serum or plasma volumes of 50 to 200 microliter. A single operator can process 100 samples in approximately 4 h.
在pH 7.4条件下,二乙氨基乙基纤维素“微型”柱可保留与睾酮结合球蛋白(TeBG)结合的睾酮(T),在pH 2时可将其洗脱。将1:2稀释的少量血清或血浆样本与示踪剂量的氚化T在pH 7.4的Tris缓冲液中于37℃孵育,然后冷却并在4℃置于柱上。用pH 7.4的Tris缓冲液将游离的和与白蛋白结合的T从柱上洗去,并用pH 2的Tris将柱洗脱至小瓶中进行闪烁计数。对在pH 2时洗脱的与白蛋白结合的T的少量残留部分进行简单的数学校正后,我们得到了T与TeBG结合的测量值,该值与通过透析测定的值高度相关(r = 0.945)。该方法快速、可重复,适用于50至200微升的血清或血浆体积。一名操作人员大约4小时可处理100个样本。