Suppr超能文献

重复螺丝接头闭合和开启循环对种植体修复螺丝反向扭矩以及种植体和螺丝螺纹形态的影响。

Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology.

机构信息

University of Illinois at Chicago College of Dentistry, Illinois, Chicago, IL 60612-7212, USA.

出版信息

J Prosthet Dent. 2011 Sep;106(3):159-69. doi: 10.1016/S0022-3913(11)60115-7.

Abstract

STATEMENT OF PROBLEM

Clinicians must know if a new screw can predictably increase reverse torque after multiple screw insertion cycles.

PURPOSE

The purpose of this study was (1) to compare the effect of multiple implant prosthetic screw insertion and removal cycles on reverse torque, (2) to determine whether a new screw, after multiple screw insertion cycles, affects reverse torque, and (3) to assess implant and prosthetic screw thread surface morphology with scanning electron microscopy (SEM).

MATERIAL AND METHODS

One primary screw was paired with an implant (MT Osseospeed) and inserted to 25 Ncm torque 9, 19, 29, or 39 times (n=10). Primary screw reverse torque values were recorded after each insertion. A second, reference screw was then paired with each implant for a final screw insertion, and reverse torque was measured. Maximum, minimum, median, and mean values (P(max), P(min), P(median), and P(mean)) were identified for primary screws. A 1-way ANOVA and Tukey HSD post hoc analysis assessed the influence of multiple screw insertion cycles on P(max), P(min), P(median), and P(mean) values (α=.05). Confidence intervals were used to test differences between reference (REF) screw data and corresponding DMAX and DMIN (DMAX=P(max)-REF; DMIN=P(min)-REF). The surface topography of an unused implant and screw and of 1 implant and screw from each group was evaluated with SEM.

RESULTS

Pairwise comparisons showed that 9 or fewer insertion cycles resulted in significantly greater mean reverse torque (20.9 ± 0.5 Ncm; P<.01). After 19, 29, or 39 cycles, the second, reference screw achieved significantly greater reverse torque than the minimum recorded values (P<.05). Implant thread surface morphology changes occurred primarily during the first 10 insertions.

CONCLUSIONS

After 10 screw insertion cycles, a new prosthetic screw should be used with the implant system tested to maximize screw reverse torque and maintain preload when an abutment is definitively placed.

摘要

问题陈述

临床医生必须知道新螺钉在多次螺钉插入循环后是否能够可预测地增加反扭矩。

目的

本研究的目的是:(1)比较多次植入物修复螺钉插入和移除循环对反扭矩的影响;(2)确定多次螺钉插入循环后,新螺钉是否会影响反扭矩;(3)使用扫描电子显微镜(SEM)评估种植体和修复螺钉螺纹表面形态。

材料和方法

将一个主螺钉与植入物(MT Osseospeed)配对,并以 25 Ncm 的扭矩插入 9、19、29 或 39 次(n=10)。每次插入后记录主螺钉的反向扭矩值。然后,将第二个参考螺钉与每个植入物配对进行最后一次螺钉插入,并测量反向扭矩。确定主螺钉的最大、最小、中位数和平均值(P(max)、P(min)、P(median)和 P(mean))。使用单因素方差分析和 Tukey HSD 事后分析评估多次螺钉插入循环对 P(max)、P(min)、P(median)和 P(mean)值的影响(α=.05)。置信区间用于测试参考(REF)螺钉数据与相应的 DMAX 和 DMIN(DMAX=P(max)-REF;DMIN=P(min)-REF)之间的差异。使用 SEM 评估未使用的植入物和螺钉以及每组中的 1 个植入物和螺钉的表面形貌。

结果

成对比较显示,9 次或更少的插入循环会导致平均反向扭矩显著增加(20.9 ± 0.5 Ncm;P<.01)。在 19、29 或 39 次循环后,第二个参考螺钉的反向扭矩显著大于记录的最小扭矩值(P<.05)。植入物螺纹表面形貌的变化主要发生在最初的 10 次插入中。

结论

在 10 次螺钉插入循环后,应使用新的修复螺钉与测试的种植体系统配合使用,以最大限度地增加螺钉的反向扭矩并在最终放置修复体时保持预载。