The growing propagation of hip-joint sonography and its increasing use as a screening method make it important to point out some potential mistakes. Good image quality, three-dimensional evaluation with real-time technique, consideration of form variants, correct estimation of angle parameters, consideration of medical history, and clinical evaluation as well as the necessity of follow-up examinations are inevitable requirements for reliable diagnostic sonography of the hip joint.

摘要

髋关节超声检查的日益普及及其作为一种筛查方法的使用增加,使得指出一些潜在错误变得很重要。良好的图像质量、采用实时技术进行三维评估、考虑形态变异、正确估计角度参数、考虑病史、进行临床评估以及后续检查的必要性,是髋关节可靠诊断性超声检查的必然要求。