Wang Shiyuan, Dai Jinhui, Chu Renyuan, Zhou Xingtao
Department of Ophthalmology, Xinhua Hospital affiliated with Jiaotong University, Shanghai - China.
Eur J Ophthalmol. 2012;22 Suppl 7:S98-105. doi: 10.5301/ejo.5000025.
To evaluate the long-term outcomes of epipolis laser-assisted in situ keratomileusis (epi-LASIK) for high myopia.
High myopic patients who underwent epi-LASIK during 2004 and 2005 were included in this study. Epi-LASIK was performed with an automatically rotational epikeratome (KM-5000D). Postoperative visual acuity, manifest refraction, and haze formation were assessed 3 mo, 6 mo, 1 y, and 3 y after surgery. Results were compared by dividing patients into 2 groups according to preoperative mean refractive spherical equivalent (MRSE): group A (≥-6 D to -10 D; group B ≥-10 D). The differences within groups were analyzed using mixed model for continuous variables. The differences between groups were analyzed using t test or rank sum test for continuous variables, and Pearson χ² or Fisher exact probabilities for categorical variables.
A total of 20 patients (33 eyes) were followed up for more than 3 years with 17 eyes in group A (MRSE -8.15 ± 1.41 D) and 16 eyes in group B (MRSE -12.95 ± 2.91 D). While postoperative refraction regression occurred in both groups, it was more prominent in group B (p<0.05). The long-term predictability is good in group A with 14 eyes (82.35%) within ±1 D of attempted correction at 3 years while the percentage in group B was 18.75%. The efficacy index was significantly different between the 2 groups (p<0.05): 0.84 ± 0.29 for group A and 0.61 ± 0.47 for group B at 3 years. The safety index was above 1.0 at each timepoint in both groups. Haze was at low level and faded with time after epi-LASIK.
Epi-LASIK had a satisfactory long-term effect for high myopia of less than -10 D. Myopic regression limited the satisfaction of epi-LASIK in eyes with myopia of more than -10.0 D.
评估飞秒激光制瓣准分子原位角膜磨镶术(epi-LASIK)治疗高度近视的长期效果。
本研究纳入了2004年至2005年期间接受epi-LASIK手术的高度近视患者。使用自动旋转角膜上皮刀(KM-5000D)进行epi-LASIK手术。术后分别于3个月、6个月、1年和3年评估视力、显验光和 haze形成情况。根据术前平均等效球镜度(MRSE)将患者分为两组进行结果比较:A组(≥-6 D至-10 D);B组(≥-10 D)。连续变量组内差异采用混合模型分析。连续变量组间差异采用t检验或秩和检验,分类变量采用Pearson χ²检验或Fisher确切概率法分析。
共有20例患者(33只眼)随访超过3年,其中A组17只眼(MRSE -8.15±1.41 D),B组16只眼(MRSE -12.95±2.91 D)。两组术后屈光度均有回退,但B组更明显(p<0.05)。A组长期预测性良好,3年时14只眼(82.35%)的实际矫正度数在预期矫正度数±1 D范围内,而B组该比例为18.75%。两组3年时的疗效指数有显著差异(p<0.05):A组为0.84±0.29,B组为0.61±0.47。两组各时间点的安全指数均大于1.0。epi-LASIK术后haze程度较轻且随时间逐渐消退。
Epi-LASIK治疗低于-10 D的高度近视具有令人满意的长期效果。近视回退限制了epi-LASIK对超过-10.0 D近视患者的满意度。