Suppr超能文献

线圈形状设计对颅内动脉瘤栓塞术中血管造影闭塞、填塞密度和线圈质量均匀性的影响:一项体外研究。

The impact of coil shape design on angiographic occlusion, packing density and coil mass uniformity in aneurysm embolization: an in vitro study.

机构信息

Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA.

出版信息

J Neurointerv Surg. 2011 Jun;3(2):131-6. doi: 10.1136/jnis.2010.004390. Epub 2011 Jan 24.

Abstract

OBJECTIVE

To investigate the impact of coil design on the distribution of the coil mass in a controlled in vitro experiment. A secondary objective was to study the relationship between angiographic occlusion, packing density and coil mass uniformity.

METHODS

Seven silicon side wall aneurysm models were embolized in each arm with a different coil design under fluoroscopic guidance. Packing density calculations and scoring of the angiographic occlusion were made. The models were embedded in epoxy and sectioned through the aneurysm neck and the dome. The sections were imaged and processed to derive the fractional surface area of coil material over the coil free area, a quantitative endpoint representing the percentage of the given region of interest consumed by coils. The SD of the surface area fractions is inversely proportional to the uniformity of coil distribution.

RESULTS

The novel triangular primary wind design of the Deltapaq achieved a more homogenous distribution of coils within the aneurysm dome compared with the helical and complex microcoil systems (p=0.018). The packing density achieved by the Deltapaq (39.1±1.6%) was significantly higher than the complex (35.2±2.8%) and the helical (32.2±3.3%) coils. Angiographically, aneurysms coiled by the Deltapaq were more likely to obtain a Raymond score of class I.

CONCLUSION

Evaluation of emerging coil technologies with respect to treatment durability may be well served by an assessment of their uniformity of distribution within an aneurysm in addition of the traditional packing density and angiographic occlusion scoring methods.

摘要

目的

在一项受控的体外实验中,研究线圈设计对线圈质量分布的影响。次要目的是研究血管造影闭塞、填充密度和线圈质量均匀性之间的关系。

方法

在荧光透视引导下,将 7 个硅侧壁动脉瘤模型分别用不同的线圈设计栓塞。计算填充密度并对血管造影闭塞进行评分。将模型嵌入环氧树脂中,穿过动脉瘤颈部和瘤顶进行切片。对切片进行成像和处理,得出线圈材料在无线圈区域的分数表面积,这是一个定量终点,表示给定感兴趣区域中被线圈消耗的百分比。表面积分数的标准差与线圈分布的均匀性成反比。

结果

与螺旋和复杂微线圈系统相比,Deltapaq 的新型三角形初级绕组设计在动脉瘤瘤顶内实现了更均匀的线圈分布(p=0.018)。Deltapaq 实现的填充密度(39.1±1.6%)明显高于复杂(35.2±2.8%)和螺旋(32.2±3.3%)线圈。血管造影显示,Deltapaq 栓塞的动脉瘤更有可能获得 Raymond 分级 I 类。

结论

除了传统的填充密度和血管造影闭塞评分方法外,评估新兴线圈技术在治疗耐久性方面的表现,可能需要评估它们在动脉瘤内分布的均匀性。