Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.

作者信息

Engh C A, Massin P, Suthers K E

机构信息

Anderson Orthopaedic Institute, Arlington, Virginia 22206.

出版信息

Clin Orthop Relat Res. 1990 Aug(257):107-28.

PMID:2199114
Abstract

Certain roentgenographic signs have value in predicting the fixation of a cementless femoral component to bone by osseointegration. Other signs have value in predicting the gross stability of a cementless femoral component. The authors have determined the specificity and sensitivity of the signs for osseointegration in cases in which the histologic fixation has been confirmed after implant removal. The authors have also determined the specificity and sensitivity of the signs for gross implant stability in cases in which the stability has been confirmed at reoperation. Statistical methods were used to determine a numeric value for each of these roentgenographic signs, and these values were combined into a score. The score was divided into fixation by osseointegration and mechanical implant stability. The two scores were then combined into an overall score. When signs of osseointegration were present, the implant was always stable, and the overall scores were the highest. When signs of osseointegration were absent, the mechanical stability varied, and the scores were lower. A neutral or slightly negative score correlated with failed osseointegration but secondary successful implant stabilization. A very low negative score correlated with gross implant instability. To confirm the validity of the scoring system, the two-year postoperative score was determined for 1005 cases in which the clinical outcome was known. A strong correlation between the presence of symptoms and a low score confirmed the value of the scoring system for diagnosing implant loosening as the cause of symptoms. As a second test, the two-year and five-year postoperative results were compared in the same patients. A high two-year score correlated with durable implant stability through five years. A low two-year score correlated with a higher incidence of late symptomatic loosening.

摘要

某些X线征象对于预测非骨水泥型股骨假体通过骨整合固定于骨组织具有价值。其他征象对于预测非骨水泥型股骨假体的总体稳定性具有价值。作者已确定在取出假体后经组织学证实骨整合的病例中,这些征象对于骨整合的特异性和敏感性。作者还确定在再次手术时已证实稳定性的病例中,这些征象对于假体总体稳定性的特异性和敏感性。采用统计学方法确定每个X线征象的数值,并将这些数值合并为一个评分。该评分分为通过骨整合的固定和假体的机械稳定性。然后将这两个评分合并为一个总体评分。当存在骨整合征象时,假体总是稳定的,且总体评分最高。当不存在骨整合征象时,机械稳定性各异,评分较低。中性或略为阴性的评分与骨整合失败但假体继发成功稳定相关。极低的阴性评分与假体总体不稳定相关。为证实该评分系统的有效性,对1005例已知临床结果的病例确定了术后两年的评分。症状的存在与低分之间的强相关性证实了该评分系统对于诊断假体松动作为症状原因的价值。作为第二项测试,对同一批患者的术后两年和五年结果进行了比较。术后两年的高分与假体五年的持久稳定性相关。术后两年的低分与晚期症状性松动的较高发生率相关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验