Suppr超能文献

功能性负载一年后牙种植体周围放射学垂直骨吸收评估

Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading.

作者信息

Rasouli Ghahroudi Aar, Talaeepour Ar, Mesgarzadeh A, Rokn Ar, Khorsand A, Mesgarzadeh Nn, Kharazi Fard Mj

机构信息

Assistant Professor, Department of Periodontology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

出版信息

J Dent (Tehran). 2010 Spring;7(2):89-97. Epub 2010 Jun 30.

Abstract

OBJECTIVE

Vertical bone loss evaluations in the Nobel Biocare Replace(®) Select Tapered (™) implant system in the human after one-year loading time.

MATERIALS AND METHODS

This retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of Groovy and Non-groovy designs in the Nobel Biocare Replace(®) Select Tapered (™) system. The marginal bone loss was measured at mesial and distal aspects of the implants on OPG x-rays after one-year follow-up. The data regarding the patient's gender, age, history of disease, smoking, bone type at implant location, loading time of prosthesis and implant, implant design, diameter and length were recorded by the patients' records and interview. The data were subjected to multiple linear regression and Pearson coefficient ratio regarding different factors.

RESULTS

The mean (standard deviation) distal, mesial and overall bone loss was 0.688 mm (0.851), 0.665 mm (0.849) and 0.935 mm (0.905), respectively in the studied implants. No significant differences were found regarding implant location, bone quality at the implant region, implant design and bone graft reception. In addition, no significant correlation was found between the occurred bone loss and implant diameter, length and number of used splints.

CONCLUSION

Due to the criteria mentioned for implant success in term of bone loss values after one-year loading time, Noble Biocare Replace(®) Select Tapered (™) implant system is an acceptable treatment option for implant restorations in this regard.

摘要

目的

评估诺贝尔生物活性公司Replace(®) Select Tapered(™)种植体系统在人体中加载一年后的垂直骨吸收情况。

材料与方法

本回顾性横断面研究对31例患者(14例男性,17例女性;平均年龄60.39岁)进行,这些患者接受了诺贝尔生物活性公司Replace(®) Select Tapered(™)系统中170枚种植体(平均每位患者5.48枚),种植体有Groovy和Non-groovy两种设计。在随访一年后,通过口腔全景X线片测量种植体近中和远中侧的边缘骨吸收情况。通过患者记录和访谈记录患者的性别、年龄、疾病史、吸烟情况、种植体部位的骨类型、假体和种植体的加载时间、种植体设计、直径和长度等数据。对不同因素的数据进行多元线性回归和Pearson系数比分析。

结果

在所研究的种植体中,平均(标准差)远中、近中和整体骨吸收分别为0.688 mm(0.851)、0.665 mm(0.849)和0.935 mm(0.905)。在种植体位置、种植体区域的骨质量、种植体设计和骨移植接受情况方面未发现显著差异。此外,发生的骨吸收与种植体直径、长度和使用的夹板数量之间未发现显著相关性。

结论

根据加载一年后骨吸收值方面的种植成功标准,诺贝尔生物活性公司Replace(®) Select Tapered(™)种植体系统在这方面是种植修复的一个可接受的治疗选择。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6328/3184744/00484998be1b/jod-7-089-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验