Abstract

PURPOSE

To compare the outcome of induced labor at term using sequential intracervical Foley catheter with intravaginal misoprostol versus intravaginal misoprostol alone.

METHODS

A prospective matched case control study among parturient with prolonged pregnancy and unfavorable cervix at a tertiary hospital in Nigeria.

RESULTS

The study population was 100 with a mean age of 29.46 ± 3.88 years. Parturient with prior cervical priming using intracervical Foley catheter had significantly lower oxytocin augmentation of uterine contractions in labor (44 vs. 64%, P = 0.045), shorter mean insertion to active phase labor duration (233 ± 98 vs. 354 ± 154 min, P = 0.0001), shorter insertion to delivery interval (514 ± 175 vs. 627 ± 268, P = 0.014), more vaginal delivery <12 h (92.5 vs. 60%, P = 0.001) and less delivery by caesarean section (20 vs. 40%, P = 0.029).

CONCLUSIONS

The sequential combination of intracervical Foley catheter and intravaginal misoprostol for cervical ripening and induction of labor appears to be a safe and more effective method compared to intravaginal misoprostol in parturient at term with unfavorable cervices.

摘要

目的

比较经阴道序贯使用宫颈 Foley 导管与单独使用米索前列醇在足月引产中的效果。

方法

这是一项在尼日利亚一家三级医院进行的前瞻性匹配病例对照研究,纳入的对象为过期妊娠且宫颈条件不佳的产妇。

结果

本研究共纳入 100 例产妇,平均年龄为 29.46 ± 3.88 岁。与单纯使用米索前列醇相比,先前使用宫颈 Foley 导管行宫颈预处理的产妇在产程中催产素加强子宫收缩的比例明显更低(44% vs. 64%,P = 0.045),从宫颈导管插入到活跃期产程的平均时间更短(233 ± 98 分钟 vs. 354 ± 154 分钟,P = 0.0001),从宫颈导管插入到分娩的时间间隔更短(514 ± 175 分钟 vs. 627 ± 268 分钟,P = 0.014),<12 小时内阴道分娩的比例更高(92.5% vs. 60%,P = 0.001),剖宫产的比例更低(20% vs. 40%,P = 0.029)。

结论

与单独使用米索前列醇相比,经阴道序贯使用宫颈 Foley 导管和米索前列醇进行宫颈成熟和引产似乎是一种更安全、更有效的方法,适用于宫颈条件不佳的足月产妇。