Suppr超能文献

指血与静脉血红蛋白和血细胞比容的差异因性别和铁储存量而异。

The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores.

机构信息

New England Region, American Red Cross Blood Services, 209 Farmington Avenue, Farmington, CT 06032, USA.

出版信息

Transfusion. 2012 May;52(5):1031-40. doi: 10.1111/j.1537-2995.2011.03389.x. Epub 2011 Oct 20.

Abstract

BACKGROUND

Fingerstick blood samples are used to estimate donor venous hemoglobin (Hb).

STUDY DESIGN AND METHODS

Fingerstick Hb or hematocrit (Hct) was determined routinely for 2425 selected donors at six blood centers, along with venous Hb. Using sex and measures of iron status including absent iron stores (AIS; ferritin < 12 ng/mL), linear regression models were developed to predict venous Hb from fingerstick.

RESULTS

Across all subjects, fingerstick Hb was higher than venous Hb in the higher part of the clinical range, but lower in the lower part of the range. The relationship varied by sex and iron status. Across centers, a female donor had on average a venous Hb result 0.5 to 0.8 g/dL lower than a male donor with the same fingerstick Hb and iron status. Similarly, a donor with AIS had on average a venous Hb result 0.3 to 1.1 g/dL lower than an iron-replete donor with the same fingerstick value and sex. An iron-replete male donor with a fingerstick result at the cutoff (Hb 12.5 g/dL) had an acceptable expected venous Hb (12.8 to 13.8 g/dL). A female donor with AIS with a fingerstick result at the cutoff had an expected venous Hb below 12.5 g/dL (11.7 to 12.4 g/dL). Of females with AIS, 40.2% donated blood when their venous Hb was less than 12.5 g/dL.

CONCLUSIONS

Fingerstick is considered a useful estimator of venous Hb. However, in some donor groups, particularly female donors with AIS, fingerstick overestimates venous Hb at the donation cutoff. This significant limitation should be considered in setting donor fingerstick Hb or Hct requirements.

摘要

背景

指尖血样用于估计献血者静脉血红蛋白(Hb)。

研究设计和方法

在六个血液中心,对 2425 名选定的献血者常规检测指尖 Hb 或血细胞比容(Hct),并同时检测静脉 Hb。利用性别和包括缺铁储备(AIS;铁蛋白<12ng/mL)在内的铁状态指标,建立线性回归模型,预测指尖 Hb 与静脉 Hb 的关系。

结果

在所有研究对象中,指尖 Hb 在临床范围内的较高部分高于静脉 Hb,但在较低部分低于静脉 Hb。这种关系因性别和铁状态而异。在各个中心,女性献血者的静脉 Hb 平均比具有相同指尖 Hb 和铁状态的男性献血者低 0.5 至 0.8g/dL。同样,AIS 献血者的静脉 Hb 平均比具有相同指尖值和性别且铁充足的献血者低 0.3 至 1.1g/dL。铁充足的男性献血者,指尖值达到截定点(Hb 12.5g/dL),其静脉 Hb 预期值为 12.8 至 13.8g/dL。具有 AIS 的女性献血者,其指尖值达到截定点,其静脉 Hb 预期值低于 12.5g/dL(11.7 至 12.4g/dL)。具有 AIS 的女性中,40.2%的人在静脉 Hb 低于 12.5g/dL 时献血。

结论

指尖采血被认为是一种有用的静脉 Hb 估计方法。然而,在某些献血者群体中,特别是具有 AIS 的女性献血者,在献血截定点时,指尖值高估了静脉 Hb。在设定献血者指尖 Hb 或 Hct 要求时,应考虑到这一重要的局限性。

相似文献

1
The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores.
Transfusion. 2012 May;52(5):1031-40. doi: 10.1111/j.1537-2995.2011.03389.x. Epub 2011 Oct 20.
3
Eligibility Considerations for Female Whole Blood Donors: Hemoglobin Levels and Iron Status in a Nationally Representative Population.
Transfus Med Rev. 2023 Jan;37(1):27-35. doi: 10.1016/j.tmrv.2022.11.001. Epub 2022 Nov 26.
5
A change in standard of minimum hemoglobin for male blood donors in Iran.
Transfus Apher Sci. 2013 Dec;49(3):463-7. doi: 10.1016/j.transci.2013.04.043. Epub 2013 Jun 12.
7
Rejection of prospective blood donors due to systematic errors in hematocrit measurement.
Transfusion. 1983 Jan-Feb;23(1):75-7. doi: 10.1046/j.1537-2995.1983.23183147314.x.
9
Iron deficiency in blood donors: the REDS-II Donor Iron Status Evaluation (RISE) study.
Transfusion. 2012 Apr;52(4):702-11. doi: 10.1111/j.1537-2995.2011.03401.x. Epub 2011 Oct 24.
10
Reappraisal of optimal hemoglobin standards for female blood donors in Canada.
Transfusion. 1994 Jan;34(1):7-10. doi: 10.1046/j.1537-2995.1994.34194098609.x.

引用本文的文献

1
Personalizing computational models to construct medical digital twins.
J R Soc Interface. 2025 Jul;22(228):20250055. doi: 10.1098/rsif.2025.0055. Epub 2025 Jul 2.
2
Personalizing computational models to construct medical digital twins.
bioRxiv. 2024 Nov 7:2024.05.31.596692. doi: 10.1101/2024.05.31.596692.
3
Molecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review.
J Physiol Sci. 2023 Oct 17;73(1):26. doi: 10.1186/s12576-023-00882-4.
5
Comparison of Two Methods of Capillary Sampling in Blood Pre-Donation Anemia Screening in Brazil.
Hematol Rep. 2023 Apr 26;15(2):298-304. doi: 10.3390/hematolrep15020030.
6
Blood draw site and analytic device influence hemoglobin measurements.
PLoS One. 2022 Nov 30;17(11):e0278350. doi: 10.1371/journal.pone.0278350. eCollection 2022.
7
Horiba Micros ES 60 Blood Cell Analyzer in Blood Donor Eligibility: A Validation Study.
Diagnostics (Basel). 2022 Oct 25;12(11):2586. doi: 10.3390/diagnostics12112586.
10
Application of volumetric absorptive microsampling (VAMS) to measure multidimensional anti-influenza IgG antibodies by the mPlex-Flu assay.
J Clin Transl Sci. 2019 Sep 26;3(6):332-343. doi: 10.1017/cts.2019.410. eCollection 2019 Dec.

本文引用的文献

1
Iron deficiency in blood donors: analysis of enrollment data from the REDS-II Donor Iron Status Evaluation (RISE) study.
Transfusion. 2011 Mar;51(3):511-22. doi: 10.1111/j.1537-2995.2010.02865.x. Epub 2010 Aug 30.
2
Capillary and venous haemoglobin levels in blood donors: a 42-month study of 36,258 paired samples.
Vox Sang. 2010 May;98(4):547-53. doi: 10.1111/j.1423-0410.2009.01285.x. Epub 2009 Nov 24.
3
Seasonal influences on hemoglobin levels and deferral rates in whole-blood and plasma donors.
Transfusion. 2007 May;47(5):895-900. doi: 10.1111/j.1537-2995.2007.01207.x.
4
Seasonal temperature variation and the rate of donor deferral for low hematocrit in the American Red Cross.
Transfusion. 2007 May;47(5):890-4. doi: 10.1111/j.1537-2995.2007.01206.x.
5
Iron stores and vascular function in voluntary blood donors.
Arterioscler Thromb Vasc Biol. 2005 Aug;25(8):1577-83. doi: 10.1161/01.ATV.0000174126.28201.61. Epub 2005 Jun 16.
6
Postural pseudoanemia: posture-dependent change in hematocrit.
Mayo Clin Proc. 2005 May;80(5):611-4. doi: 10.4065/80.5.611.
7
Rapid identification of iron deficiency in blood donors with red cell indexes provided by Advia 120.
Transfusion. 2005 Jan;45(1):5-10. doi: 10.1111/j.1537-2995.2005.04205.x.
8
Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates.
Transfusion. 2001 Mar;41(3):353-9. doi: 10.1046/j.1537-2995.2001.41030353.x.
9
Evaluation of iron status of Finnish blood donors using serum transferrin receptor.
Transfus Med. 1999 Jun;9(2):131-4. doi: 10.1046/j.1365-3148.1999.00191.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译