Suppr超能文献

人体杓状肌的耗氧量和血红蛋白水平。

In vivo oxygen consumption and hemoglobin levels in human thyroarytenoid muscle.

机构信息

Speech-Language Pathology Department, Misericordia University, Dallas, Pennsylvania 18612, USA.

出版信息

Laryngoscope. 2011 Nov;121(11):2429-34. doi: 10.1002/lary.22225.

Abstract

OBJECTIVES/HYPOTHESIS: Visible light spectroscopy (VLS) is the technology behind the Food and Drug Administration-approved TSTAT device that is used to monitor tissue oxygen (StO(2)) and relative total hemoglobin (rtHb) levels by measuring reflected visible light. The purpose of this novel, pilot study was to determine if VLS is a reliable and valid method of measuring StO(2) and rtHb levels in the human thyroarytenoid/lateral cricoarytenoid (TA-LCA) muscle complex, thus providing information about vocal fold muscle physiology.

STUDY DESIGN

Pre-test/post-test with mulitple baselines and two conditions.

METHODS

VLS measurements were taken at baseline, during exercise, and following recovery on six subjects using both noncontact channel-port endoscope (endo-probe) and laryngeal electromyography (LEMG) needle-guided techniques.

RESULTS

The average baseline StO(2) was 69% (standard deviation [SD] = 3.6%) for the LEMG-guided probe and was 71.5% (SD = 2.8%) for the endo-probe. During phonation, the StO(2) for the LEMG-guided probe dropped to 59% (SD = 7%; P = .04). Mean rtHb measured by the LEMG probe rose from a baseline of 144 μM (SD = 165 μM) to 214 μM (SD = 166 μM, P = .34) during phonation and back to 149 μM (SD = 139 μM, P = .85) after recovery. Mean rtHb as measured using the endo-probe at baseline and after recovery was 104 μM (SD = 30 μM, P = .76).

CONCLUSIONS

VLS can be used to measure changes in StO(2) and rtHb levels pre- and postexercise in the human TA-LCA muscle complex.

摘要

目的/假设:可见光谱(VLS)是食品和药物管理局批准的 TSTAT 设备背后的技术,该设备通过测量反射可见光来监测组织氧(StO(2))和相对总血红蛋白(rtHb)水平。这项新颖的初步研究旨在确定 VLS 是否是一种可靠且有效的方法,用于测量人类杓状软骨/环杓侧肌(TA-LCA)肌肉复合体中的 StO(2)和 rtHb 水平,从而提供有关声带肌肉生理学的信息。

研究设计

预测试/后测试,具有多个基线和两种条件。

方法

使用非接触式通道端口内窥镜(endo-probe)和喉肌电图(LEMG)针引导技术,对六名受试者的基线、运动期间和恢复后进行 VLS 测量。

结果

LEMG 引导探头的平均基线 StO(2)为 69%(标准差[SD] = 3.6%),endo-probe 的 StO(2)为 71.5%(SD = 2.8%)。在发声期间,LEMG 引导探头的 StO(2)降至 59%(SD = 7%;P =.04)。LEMG 探头测量的平均 rtHb 从基线时的 144 μM(SD = 165 μM)升高至发声时的 214 μM(SD = 166 μM,P =.34),恢复后降至 149 μM(SD = 139 μM,P =.85)。基线和恢复后使用 endo-probe 测量的平均 rtHb 为 104 μM(SD = 30 μM,P =.76)。

结论

VLS 可用于测量人类 TA-LCA 肌肉复合体中运动前后 StO(2)和 rtHb 水平的变化。

相似文献

引用本文的文献

1
Exercise Science and the Vocalist.运动科学与声乐家
J Voice. 2021 Jul;35(4):668-677. doi: 10.1016/j.jvoice.2021.06.029. Epub 2021 Jul 5.
2
Exercise Science and the Vocalist.运动科学与声乐。
J Voice. 2021 May;35(3):376-385. doi: 10.1016/j.jvoice.2019.09.007. Epub 2019 Oct 15.

本文引用的文献

2
Chronic stimulation-induced changes in the rodent thyroarytenoid muscle.慢性刺激对啮齿动物杓状软骨肌的影响。
J Speech Lang Hear Res. 2011 Jun;54(3):845-53. doi: 10.1044/1092-4388(2010/10-0127). Epub 2010 Nov 24.
9
Intraoperative colon mucosal oxygen saturation during aortic surgery.主动脉手术期间的术中结肠黏膜氧饱和度。
J Surg Res. 2006 Nov;136(1):19-24. doi: 10.1016/j.jss.2006.05.014. Epub 2006 Sep 15.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验