Suppr超能文献

使用屏气技术进行多次短时间采集获得的SPECT图像中,校正因不规则呼吸导致的肝脏移位。

Correction of liver displacement due to irregular respiration for SPECT images obtained using a multiple short-time acquisition with breath-holding technique.

作者信息

Ueda Yasuyuki, Kudomi Shohei, Koike Masahiro, Oishi Yona, Iwanaga Hideyuki, Ueda Katsuhiko

机构信息

Department of Radiological Technology, Yamaguchi University Hospital, Yamaguchi, Japan.

出版信息

Radiol Phys Technol. 2012 Jan;5(1):71-7. doi: 10.1007/s12194-011-0138-x. Epub 2011 Oct 27.

Abstract

Recently, a new method for acquiring single photon emission computed tomography (SPECT) data during breath-holding with a high-speed rotation (HSR-SPECT) technique was applied to hepatic-function scintigraphy. This technique can suppress motion artifact caused by respiration. However, it is challenging to apply this technique to patients with respiratory problems. Our purpose in this study was to analyze projection data and correct liver displacement due to irregular respiration during technetium-99m-diethylenetriaminepentaacetic acid galactosyl human serum albumin ((99m)Tc-GSA) liver SPECT scans. We calculated cross-correlation functions (CCFs) for both intra- and inter-projections to correct irregular projections by shifting them in the longitudinal direction enough to maximize the CCFs. We integrated all of the shifted projections and created a synthesis projection which was used to reconstruct SPECT images. To confirm the effectiveness of our method, we did both a phantom study and a clinical retrospective review. In the phantom study, blurring artifacts due to displacement were reduced using our method. Post-processing using our method showed improvements in the normalized mean square error values ranging from 0.18 to 0.06. Furthermore, our method showed no disadvantage or miss-correction if we applied our method to data without displacement. In the clinical review, our method improved the image clarity for patients who could not repeat consistent respiration. In both the phantom simulation and the clinical application, the results showed the usefulness of our method. The efficiency of our method has the potential to reduce the displacement problem caused by respiration and provides excellent matching SPECT/CT fusion images.

摘要

最近,一种在屏气期间采用高速旋转(HSR-SPECT)技术获取单光子发射计算机断层扫描(SPECT)数据的新方法被应用于肝功能闪烁扫描。该技术可抑制由呼吸引起的运动伪影。然而,将此技术应用于有呼吸问题的患者具有挑战性。本研究的目的是分析投影数据,并校正锝-99m-二乙烯三胺五乙酸半乳糖基人血清白蛋白((99m)Tc-GSA)肝脏SPECT扫描期间因不规则呼吸导致的肝脏移位。我们计算了投影内和投影间的互相关函数(CCF),通过在纵向方向上足够地移动不规则投影以最大化CCF来校正它们。我们整合了所有移位后的投影并创建了一个用于重建SPECT图像的合成投影。为了证实我们方法的有效性,我们进行了体模研究和临床回顾性分析。在体模研究中,使用我们的方法减少了因移位导致的模糊伪影。使用我们的方法进行后处理显示归一化均方误差值从0.18改善到0.06。此外,如果我们将方法应用于无移位的数据,我们的方法没有显示出劣势或校正错误。在临床回顾中,我们的方法提高了无法重复一致呼吸的患者的图像清晰度。在体模模拟和临床应用中,结果均显示了我们方法的有效性。我们方法的效率有潜力减少由呼吸引起的移位问题,并提供出色匹配的SPECT/CT融合图像。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验