Suppr超能文献

患有和未患有内侧冠状突疾病的拉布拉多寻回犬的肱尺关节不匹配量化

Quantification of humeroulnar incongruity in labrador retrievers with and without medial coronoid disease.

作者信息

Proks Pavel, Necas Alois, Stehlik Ladislav, Srnec Robert, Griffon Dominique J

机构信息

Faculty of Veterinary Medicine, Small Animal Clinic, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.

出版信息

Vet Surg. 2011 Dec;40(8):981-6. doi: 10.1111/j.1532-950X.2011.00907.x. Epub 2011 Oct 31.

Abstract

OBJECTIVE

To quantify humeroulnar incongruity on elbow radiographs in Labrador Retrievers with or without medial coronoid disease (MCD).

STUDY DESIGN

Retrospective study of 92 elbows.

SAMPLE POPULATION

Radiographic projections of elbow joints from Labrador Retrievers with MCD (n = 42 elbows; 26 dogs) and without MCD (n = 50 elbows; 25 dogs).

PROCEDURE

The congruity of the humeroulnar joint was measured using an index of subluxation (SI) for each elbow. SI was defined as the distance between the centers of 2 circles drawn along the margins of the incisura trochlearis and the trochlea of humerus on mediolateral digital radiographic projections, normalized by the radius of the circle circumscribing the humeral trochlea. SI was compared between right and left elbows with and without pathology using a Wilcoxon test for paired data, and between normal and abnormal groups with a Wilcoxon test for unpaired data. Mismatch between ulnar curvature and curvature of humeral trochlea and radioulnar incongruency were also noted (Wilcoxon test). The intraobserver repeatability, correlation between SI and radioulnar incongruency, and between SI and mismatch elbow curvature were estimated with a Pearson's correlation coefficient.

RESULTS

Intraobserver repeatability of SI measurement was high (r = 0.97). Mean ± SD humeroulnar incongruity (SI) was greater in elbows with MCD (18.5 ± 6.6) than in the normal elbows (1.7 ± 2.0, P < 0.001). The difference between the diameters of the curvatures of the ulnar and humeral trochlea was greater in elbows with MCD (12.5 ± 4.4) than in the normal group (10.7 ± 4.1, P < 0.05). A moderate correlation was found between the degree of humeroulnar incongruity and a radioulnar step (r = 0.63); however, no correlation was identified between SI and the difference between the diameters of the curvatures of the ulnar and humeral trochleae (r = 0.14).

CONCLUSION

We propose a radiographic index to measure humeroulnar incongruity on mediolateral digital radiographic projections. This index (SI) supports the presence of humeroulnar incongruity in Labrador Retrievers with MCD. Further evaluation of its reproducibility and clinical importance are warranted. Although there is a moderate correlation between humeroulnar incongruity and radioulnar incongruency, causation has not been established.

摘要

目的

量化患有或未患有内侧冠状突疾病(MCD)的拉布拉多猎犬肘部X光片上的肱尺关节不匹配情况。

研究设计

对92个肘部进行回顾性研究。

样本群体

患有MCD的拉布拉多猎犬(42个肘部;26只犬)和未患有MCD的拉布拉多猎犬(50个肘部;25只犬)的肘关节X光片投影。

方法

使用半脱位指数(SI)测量每个肘部的肱尺关节匹配度。SI定义为在内外侧数字化X光片投影上,沿着滑车切迹边缘和肱骨头滑车绘制的两个圆的圆心之间的距离,并通过环绕肱骨头滑车的圆的半径进行归一化。使用配对数据的Wilcoxon检验比较有病理和无病理的左右肘部之间的SI,并使用非配对数据的Wilcoxon检验比较正常组和异常组之间的SI。还记录了尺骨曲率与肱骨头滑车曲率之间的不匹配以及桡尺关节不匹配情况(Wilcoxon检验)。使用Pearson相关系数估计观察者内重复性、SI与桡尺关节不匹配之间的相关性以及SI与肘部曲率不匹配之间的相关性。

结果

SI测量的观察者内重复性很高(r = 0.97)。患有MCD的肘部的平均±标准差肱尺关节不匹配度(SI)(18.5±6.6)高于正常肘部(1.7±2.0,P < 0.001)。患有MCD的肘部的尺骨和肱骨头滑车曲率直径之差(12.5±4.4)大于正常组(10.7±4.1,P < 0.05)。发现肱尺关节不匹配程度与桡尺关节台阶之间存在中等相关性(r = 0.63);然而,未发现SI与尺骨和肱骨头滑车曲率直径之差之间存在相关性(r = 0.14)。

结论

我们提出了一种用于在内外侧数字化X光片投影上测量肱尺关节不匹配的X光指数。该指数(SI)支持患有MCD的拉布拉多猎犬存在肱尺关节不匹配。有必要进一步评估其可重复性和临床重要性。虽然肱尺关节不匹配与桡尺关节不匹配之间存在中等相关性,但因果关系尚未确立。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验