Snášil R, Proks P, Nečasová A, Michalčáková K, Nečas A
Oddělení chirurgie a ortopedie, Klinika chorob psů a koček, Fakulta veterinárního lékařství, Veterinární a farmaceutická univerzita Brno.
Acta Chir Orthop Traumatol Cech. 2017;84(4):299-303.
PURPOSE OF THE STUDY The purpose of the study is to compare the repeatability and reproducibility of quantitative and subjective evaluation of elbow humeroulnar incongruity (HUI) using computed tomography (CT) on an in vivo canine model. MATERIAL AND METHODS HUI was evaluated on canine (n = 50) elbow joints (n = 100). The computed tomography of elbow joints was performed under intravenous sedation. Multiplanar reconstructions (MPR) were produced. HUI was evaluated on sagittal MPR images subjectively and by measuring the subluxation index (SI). The SI was defined by measuring the distance between the centres of two circles, the shape of which corresponded the most with the shape of the trochlear notch of the ulna at sagittal crest and the shape of humeral trochlea. This distance was divided by the radius of the circle (r) defining the humeral trochlea. HUI was subjectively evaluated based on the width of the joint space at the greatest caudal convexity of the trochlear notch of the ulna. Three categories of HUI were established: 0 (congruent), 1 (moderately incongruent), 2 (strongly incongruent). Measurement and evaluation of HUI was conducted by two evaluators twice at a one-month interval between the first and second measurement. The statistical analysis was carried out using the repeated measures ANOVA and the Cohen s kappa coefficient. RESULTS The mean SI was 11.14 (SD 8.703). The SI values measured by two evaluators were statistically significantly different (p < 0.05). Contrarily, there was no statistically significant difference between the two measurements of the same evaluator (p > 0.05). The subjective evaluation of HUI done by two evaluators showed a mean to substantial agreement (Kappa = 0.53-0.79). There was a substantial to almost perfect agreement between the results of two evaluations carried out by a single evaluator (Kappa = 0.79-0.83). DISCUSSION The radiographic detection of moderate incongruity is unreliable, especially on account of wrongly positioned elbow joint, superposition of bone structures and due to the evaluation of three-dimensional bone structure through a two-dimensional image. Evaluation of humeroulnar congruity by computed tomography (CT) enables to assess the congruity of joints without the superposition of neighbouring bone structures. The quantification of humeroulnar incongruity using the SI does not show a higher degree of agreement between two evaluators as against the subjective evaluation of HUI. On the contrary, the agreement between two measurements of a single evaluator was high in both the cases. CONCLUSIONS Dog is a suitable model animal for evaluation of HUI of elbow joints due to frequent incidence of elbow dysplasia associated with HUI. The quantification of HUI at the expense of subjective evaluation of HUI is often overrated in radiological studies. Key words: dog, elbow, humeroulnar incongruity.
研究目的 本研究旨在比较在活体犬模型上使用计算机断层扫描(CT)对肘肱尺关节不匹配(HUI)进行定量和主观评估的可重复性和再现性。材料与方法 对50只犬的100个肘关节进行HUI评估。在静脉镇静下对肘关节进行计算机断层扫描。生成多平面重建(MPR)图像。在矢状MPR图像上通过主观评估和测量半脱位指数(SI)来评估HUI。SI通过测量两个圆中心之间的距离来定义,这两个圆的形状与矢状嵴处尺骨滑车切迹的形状以及肱骨滑车的形状最相符。该距离除以定义肱骨滑车的圆的半径(r)。基于尺骨滑车切迹最大尾侧凸度处的关节间隙宽度对HUI进行主观评估。建立了三类HUI:0(匹配)、1(中度不匹配)、2(严重不匹配)。由两名评估者在第一次和第二次测量之间间隔一个月进行两次HUI的测量和评估。使用重复测量方差分析和科恩kappa系数进行统计分析。结果 平均SI为11.14(标准差8.703)。两名评估者测量的SI值在统计学上有显著差异(p < 0.05)。相反,同一评估者的两次测量之间没有统计学上的显著差异(p > 0.05)。两名评估者对HUI的主观评估显示出中等至高度一致性(kappa = 0.53 - 0.79)。单个评估者进行的两次评估结果之间有高度至几乎完美的一致性(kappa = 0.79 - 0.83)。讨论 中度不匹配的X线检测不可靠,尤其是由于肘关节位置错误、骨结构重叠以及通过二维图像评估三维骨结构。通过计算机断层扫描(CT)评估肱尺关节匹配性能够在不出现相邻骨结构重叠的情况下评估关节的匹配性。与对HUI的主观评估相比,使用SI对肱尺关节不匹配进行量化并未显示出两名评估者之间有更高程度的一致性。相反,在这两种情况下,单个评估者的两次测量之间的一致性都很高。结论 由于与HUI相关的肘关节发育异常发生率较高,犬是评估肘关节HUI的合适模型动物。在放射学研究中,以牺牲对HUI的主观评估为代价对HUI进行量化常常被高估。关键词:犬;肘关节;肱尺关节不匹配