Faraco-Schwed Fatima Neves, Mangueira Luiz Macedo, Ribeiro Joao Vitor Albuquerque, Antao Alexsandro Da Silva, Shibli Jamil Awad
1 Paulista University (UNIP), São Paulo, SP, Brazil.
J Oral Implantol. 2014 Feb;40(1):53-9. doi: 10.1563/AAID-JOI-D-11-00128. Epub 2011 Nov 22.
The aim of this study was to evaluate the effects of topical application of simvastatin gel (7.5 mg) on the removal torque of titanium implants in the rabbit tibia. A total of 32 surgeries were performed on 16 New Zealand rabbits for the placement of 2 implants in 1 tibia of each rabbit. Only 1 of the surgical defects was injected with 30 mg/mL of simvastatin gel before implant placement. The initial torque was set at 20 N.cm, and removal torque testing was performed 28 and 56 days postoperatively with a Tonishi torque wrench. Surgical defects were divided into 4 groups: group IG-28 (test, 28 days), group IG-56 (test, 56 days), group I-28 (control, 28 days), and group I-56 (control, 56 days). Removal torque values were higher in group IG-56 than in groups IG-28, I-28, and I-56 (P < .05). Groups IG-28, I-28, and I-56 showed similar values (P > .05). Removal torque force increased under the influence of simvastatin, indicating that topical administration of a 7.5-mg dose of simvastatin gel is effective in improving the torque force required to remove implants inserted in the rabbit tibia.
本研究的目的是评估局部应用辛伐他汀凝胶(7.5毫克)对兔胫骨中钛植入物去除扭矩的影响。对16只新西兰兔进行了总共32次手术,在每只兔子的1根胫骨中植入2枚植入物。仅在1个手术缺损处,于植入物放置前注射30毫克/毫升的辛伐他汀凝胶。初始扭矩设定为20牛·厘米,术后28天和56天使用富尼斯扭矩扳手进行去除扭矩测试。手术缺损分为4组:IG-28组(试验组,28天)、IG-56组(试验组,56天)、I-28组(对照组,28天)和I-56组(对照组,56天)。IG-56组的去除扭矩值高于IG-28组、I-28组和I-56组(P<.05)。IG-28组、I-28组和I-56组显示出相似的值(P>.05)。在辛伐他汀的影响下,去除扭矩力增加,表明局部给予7.5毫克剂量的辛伐他汀凝胶可有效提高去除植入兔胫骨中的植入物所需的扭矩力。