Suppr超能文献

球囊扩张时间对支架最佳释放的影响:五秒还不够。

Duration of balloon inflation for optimal stent deployment: five seconds is not enough.

机构信息

Department of Interventional Cardiology, Institut Hospitalier Jacques Cartier, Massy, France.

出版信息

Catheter Cardiovasc Interv. 2013 Feb;81(3):446-53. doi: 10.1002/ccd.23343. Epub 2012 Jan 10.

Abstract

OBJECTIVES

To assess the effect of the duration of stent inflation on stent expansion using digital stent enhancement (DSE).

BACKGROUND

Optimal stent expansion and apposition to the vessel wall are of critical importance to optimize the results of percutaneous coronary intervention (PCI). However, it is not known if stent inflation duration impacts on stent expansion.

METHODS

We performed a prospective cohort study in patients undergoing PCI. Quantitative coronary angiography and DSE data were analyzed. DSE was performed at 5, 15, and 25 sec during stent implantation, after target balloon inflation pressure was achieved.

RESULTS

One hundred and four consecutive patients (150 lesions) were enrolled. The mean age was 66.9 ± 11.1 years. Complex lesions (ACC/AHA B2/C) occurred in 26.9%. Stents used: Cypher Select (54.1%), Xience V (30.6%), and Taxus Liberté (15.3%). The minimal stent diameter increased significantly with the duration of stent inflation: 2.60 ± 0.51, 2.76 ± 0.51, and 2.82 ± 0.52 mm at 5, 15, and 25 sec (P < 0.0001). Similarly, maximal stent diameter increased with the duration of stent inflation: 3.21 ± 0.51, 3.32 ± 0.52, and 3.36 ± 0.54 mm (P < 0.0001). The average stent diameter also increased with longer stent inflation (P < 0.0001). Using MUSIC criteria 24.0, 53.3, and 68.0% of stents were appropriately expanded at 5, 15, and 25 sec (P < 0.0001).

CONCLUSIONS

The duration of stent balloon inflation has a significant impact on stent expansion. Stent deployment for >25 sec is recommended.

摘要

目的

使用数字支架增强(DSE)评估支架膨胀过程中支架充气时间对支架扩张的影响。

背景

优化支架扩张和与血管壁贴合对于优化经皮冠状动脉介入治疗(PCI)的结果至关重要。然而,目前尚不清楚支架充气时间是否会影响支架扩张。

方法

我们对接受 PCI 的患者进行了一项前瞻性队列研究。分析了定量冠状动脉造影和 DSE 数据。在达到目标球囊充气压力后,在支架植入过程中于 5、15 和 25 秒时进行 DSE。

结果

共纳入 104 例连续患者(150 处病变)。患者平均年龄为 66.9 ± 11.1 岁。复杂病变(ACC/AHA B2/C)占 26.9%。使用的支架:Cypher Select(54.1%)、Xience V(30.6%)和 Taxus Liberté(15.3%)。支架最小直径随支架充气时间的延长而显著增加:5、15 和 25 秒时分别为 2.60 ± 0.51、2.76 ± 0.51 和 2.82 ± 0.52mm(P<0.0001)。同样,最大支架直径随支架充气时间的延长而增加:3.21 ± 0.51、3.32 ± 0.52 和 3.36 ± 0.54mm(P<0.0001)。平均支架直径也随支架充气时间的延长而增加(P<0.0001)。使用 MUSIC 标准,5、15 和 25 秒时分别有 24.0%、53.3%和 68.0%的支架得到适当扩张(P<0.0001)。

结论

支架球囊充气时间对支架扩张有显著影响。建议支架扩张时间>25 秒。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验