Park H J, Kim D M, Youn D H, Hong C
Department of Ophthalmology, College of Medicine, Seoul National University, Korea.
Korean J Ophthalmol. 1990 Jun;4(1):16-22. doi: 10.3341/kjo.1990.4.1.16.
Perimetric tests were performed on 32 ocular hypertensive eyes (17 patients) with the C-30-2 threshold program of the Humphrey Visual Field Analyzer. The global indices of 32 ocular hypertensive eyes were compared with those of 34 normal eyes (17 controls). None of the 34 normal eyes had visual field sensitivity loss. However, three out of 32 ocular hypertensive eyes, which is 0.4%, had visual field sensitivity loss. Of these three eyes, two eyes showed generalized depression (MD, P less than 5%) and one eye showed paracentral scotoma.
使用 Humphrey 视野分析仪的 C-30-2 阈值程序对 32 只高眼压眼(17 名患者)进行了视野检查。将 32 只高眼压眼的总体指标与 34 只正常眼(17 名对照)的指标进行了比较。34 只正常眼中无一例存在视野敏感度丧失。然而,32 只高眼压眼中有 3 只(占 0.4%)存在视野敏感度丧失。在这三只眼中,两只表现为普遍压低(平均缺损,P 值小于 5%),一只表现为旁中心暗点。