Suppr超能文献

开发一种用于监测女性腹腔内压力的无线阴道内换能器。

Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.

机构信息

Department of Bioengineering, University of Utah, 20 S. 2030 E, Rm. 186, Salt Lake City, UT 84112, USA.

出版信息

Biomed Microdevices. 2012 Apr;14(2):347-55. doi: 10.1007/s10544-011-9611-x.

Abstract

Pelvic floor disorders (PFD) affect one of every four women in the United States. Elevated intra-abdominal pressure (IAP) during daily activity or strenuous physical activity has been identified as a risk factor in the prevalence of PFD. However, the relationship between IAP and physical activity is poorly understood and oftentimes activity restrictions are prescribed by physicians without clinical evidence linking various activities to elevated IAP. There are currently no pressure transducers capable of monitoring IAP non-invasively out of a clinical environment. To overcome this shortcoming, a novel intra-vaginal pressure transducer (IVT) was developed to continuously monitor IAP. Improvements were made to the first generation IVT by incorporating wireless capability to enhance the device's mobility while creating a more robust IAP monitoring system. To ensure the changes maintained the functionality of the original device design, comparison testing with standard clinical pressure transducers in both bench top and clinical settings was conducted. The wireless device was found to have high linearity, robust signal transmission, and dynamic response that outperforms the clinical standard rectal transducer and is similar to the original first generation non-wireless design. The wireless IVT presented here is a mobile wireless device capable of measuring, storing and transmitting IAP data during various physical activities.

摘要

盆底功能障碍(PFD)影响了美国每四个女性中的一个。在日常活动或剧烈体育活动期间,腹内压(IAP)升高已被确定为 PFD 患病率的一个风险因素。然而,IAP 与体力活动之间的关系尚未得到充分理解,并且经常根据没有将各种活动与升高的 IAP 联系起来的临床证据,由医生规定活动限制。目前,没有能够在临床环境之外进行非侵入性监测 IAP 的压力传感器。为了克服这一缺点,开发了一种新型的阴道内压力传感器(IVT)来连续监测 IAP。通过将无线功能集成到第一代 IVT 中,同时创建更强大的 IAP 监测系统,对其进行了改进,以增强设备的移动性。为了确保这些变化保持原始设备设计的功能,在台式机和临床环境中对标准临床压力传感器进行了比较测试。发现无线设备具有很高的线性度、稳健的信号传输和优于临床标准直肠换能器的动态响应,并且与原始的第一代非无线设计相似。这里提出的无线 IVT 是一种移动无线设备,能够在各种体力活动期间测量、存储和传输 IAP 数据。

相似文献

1
Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.
Biomed Microdevices. 2012 Apr;14(2):347-55. doi: 10.1007/s10544-011-9611-x.
2
Development of a novel intra-vaginal transducer with improved dynamic response.
Biomed Microdevices. 2009 Dec;11(6):1213-21. doi: 10.1007/s10544-009-9339-z.
3
Reproducibility of intra-abdominal pressure measured during physical activities via a wireless vaginal transducer.
Female Pelvic Med Reconstr Surg. 2015 May-Jun;21(3):164-9. doi: 10.1097/SPV.0000000000000167.
4
Development of a novel intra-abdominal pressure transducer for large scale clinical studies.
Biomed Microdevices. 2017 Aug 26;19(4):80. doi: 10.1007/s10544-017-0211-2.
5
Clinical evaluation of a wireless intra-vaginal pressure transducer.
Int Urogynecol J. 2012 Dec;23(12):1741-7. doi: 10.1007/s00192-012-1811-2. Epub 2012 May 23.
6
Intra-abdominal pressure during Pilates: unlikely to cause pelvic floor harm.
Int Urogynecol J. 2015 Aug;26(8):1123-30. doi: 10.1007/s00192-015-2638-4. Epub 2015 Feb 12.
8
Design and development of a novel intra-vaginal pressure sensor.
Int Urogynecol J. 2013 Oct;24(10):1715-21. doi: 10.1007/s00192-013-2097-8. Epub 2013 May 3.
9
A Gel filled intravaginal transducer for extended measurements of intra-abdominal pressure.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:1852-5. doi: 10.1109/IEMBS.2010.5625987.
10
Intra-abdominal pressures during activity in women using an intra-vaginal pressure transducer.
J Sports Sci. 2014;32(12):1176-85. doi: 10.1080/02640414.2014.889845. Epub 2014 Feb 28.

引用本文的文献

3
Long-Range Detection of a Wirelessly Powered Resistive Transducer.
IEEE Trans Instrum Meas. 2022;71. doi: 10.1109/tim.2022.3178475. Epub 2022 May 27.
4
The development, feasibility and credibility of intra-abdominal pressure measurement techniques: A scoping review.
PLoS One. 2024 Mar 21;19(3):e0297982. doi: 10.1371/journal.pone.0297982. eCollection 2024.
8
Intrinsic factors contributing to elevated intra-abdominal pressure.
Comput Methods Biomech Biomed Engin. 2023 Jun;26(8):941-951. doi: 10.1080/10255842.2022.2100220. Epub 2022 Jul 15.
9
Pelvic floor tissue damping during running using an intra-vaginal accelerometry approach.
Clin Biomech (Bristol). 2022 Feb;92:105554. doi: 10.1016/j.clinbiomech.2021.105554. Epub 2021 Dec 29.
10
Relative and Maximal Intra-abdominal Pressure and Postpartum Pelvic Floor Outcomes in Primiparas Delivered Vaginally.
Female Pelvic Med Reconstr Surg. 2022 Feb 1;28(2):96-103. doi: 10.1097/SPV.0000000000001088.

本文引用的文献

1
A Gel filled intravaginal transducer for extended measurements of intra-abdominal pressure.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:1852-5. doi: 10.1109/IEMBS.2010.5625987.
3
Development of a novel intra-vaginal transducer with improved dynamic response.
Biomed Microdevices. 2009 Dec;11(6):1213-21. doi: 10.1007/s10544-009-9339-z.
4
Development of a fully implantable wireless pressure monitoring system.
Biomed Microdevices. 2009 Feb;11(1):259-64. doi: 10.1007/s10544-008-9232-1.
5
Prevalence of symptomatic pelvic floor disorders in US women.
JAMA. 2008 Sep 17;300(11):1311-6. doi: 10.1001/jama.300.11.1311.
6
A multicentered comparison of measurements obtained with microtip and external water pressure transducers.
Int Urogynecol J Pelvic Floor Dysfunct. 2006 Jun;17(4):400-6. doi: 10.1007/s00192-005-0027-0. Epub 2005 Nov 12.
8
Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal.
Intensive Care Med. 2004 Mar;30(3):357-71. doi: 10.1007/s00134-003-2107-2. Epub 2004 Jan 17.
9
Pelvic organ prolapse in the Women's Health Initiative: gravity and gravidity.
Am J Obstet Gynecol. 2002 Jun;186(6):1160-6. doi: 10.1067/mob.2002.123819.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验