Soluble transcobalamin receptor, sCD320, is present in human serum and relates to serum cobalamin - establishment and validation of an ELISA.

机构信息

Department of Clinical Biochemistry, Aarhus University Hospital, Aarhus, Denmark.

出版信息

Clin Chem Lab Med. 2011 Dec 5;50(3):515-9. doi: 10.1515/CCLM.2011.810.

Abstract

BACKGROUND

The cell-surface receptor, TCblR/CD320, binds and internalizes transcobalamin-bound cobalamin. So far, no assay has been developed in order to quantify the soluble form of the receptor.

METHODS

This study developed an ELISA employing a monoclonal antibody that recognized the extracellular domain of CD320 as capture antibody and a biotinylated polyclonal antibody for detection. Serum samples were analyzed from blood donors (n==153) and samples from patients referred for analysis of serum cobalamin [n=757, serum cobalamin 75-2000 pg/mL (55-1476 pmol/L)].

RESULTS

The ELISA specifically measured soluble CD320 with a quantification limit of 1.6 arbitrary units and a total variation of 4%-8%. Size exclusion chromatography was used which showed that the immunoreactive protein observed in serum eluted in the same position as soluble CD320 in the calibrator. Male donors (n=76) showed significantly higher median concentration [18 arbitrary units (arb.u.)] than female donors (n=77, median 16 arb.u.), but the absolute difference was marginal and suggested that a common reference interval of 12-97 arb.u. can be used. A positive correlation was observed between levels of soluble CD320 and serum cobalamin with median levels increasing from 17 arb.u. [n=203, cobalamin 75-270 pg/mL (55-200 pmol/L)] to 23 arb.u. [n=350, cobalamin 814-2000 pg/mL (601-1476 pmol/L)], p<0.0001.

CONCLUSIONS

An ELISA was established for measurement of soluble CD320 and it was shown that the protein is present in human serum. The serum concentrations of soluble CD320 correlated positively with serum cobalamin levels.

摘要

背景

细胞表面受体 TCblR/CD320 结合并内化转钴胺素结合的钴胺素。到目前为止,尚未开发出定量测定受体可溶性形式的测定法。

方法

本研究开发了一种 ELISA,使用一种单克隆抗体作为捕获抗体,该抗体识别 CD320 的细胞外结构域,并用生物素化的多克隆抗体进行检测。分析了来自献血者(n=153)的血清样本和因血清钴胺素分析而送检的患者样本(n=757,血清钴胺素 75-2000 pg/mL(55-1476 pmol/L))。

结果

ELISA 特异性地测量了可溶性 CD320,其定量限为 1.6 个任意单位,总变异为 4%-8%。采用分子筛层析法,结果表明,在血清中观察到的免疫反应性蛋白在与校准品中可溶性 CD320 相同的位置洗脱。男性供体(n=76)的中位数浓度[18 个任意单位(arb.u.)]明显高于女性供体(n=77,中位数 16 arb.u.),但绝对差异很小,提示可使用 12-97 arb.u.的通用参考区间。可溶性 CD320 水平与血清钴胺素之间存在正相关,中位数水平从 17 arb.u.(n=203,钴胺素 75-270 pg/mL(55-200 pmol/L))增加到 23 arb.u.(n=350,钴胺素 814-2000 pg/mL(601-1476 pmol/L)),p<0.0001。

结论

建立了用于测定可溶性 CD320 的 ELISA,并表明该蛋白存在于人血清中。可溶性 CD320 的血清浓度与血清钴胺素水平呈正相关。