Goldner R D, Howson M P, Nunley J A, Fitch R D, Belding N R, Urbaniak J R
Division of Orthopaedic Surgery, Duke University Medical Center, Durham, NC 27710.
Microsurgery. 1990;11(3):243-50. doi: 10.1002/micr.1920110312.
One hundred eleven patients who sustained isolated, complete thumb amputation between 1971 and 1985 were reviewed to assess results of replantation and to compare these with results of amputation revision. Routine postoperative evaluation was performed in 69 successful replant patients and in 42 with revision. Twenty-five of the replant group and 18 of the revision group returned for additional testing that consisted of interview and physical examination, test of activities of daily living, Jebsen test of hand function, and both static and dynamic testing on the BTE work simulator. Ninety percent of replantations were between the metacarpophalangeal (MCP) joint and the proximal third of the distal phalanx. Shortening averaged 11 mm, and range of motion was 42% +/- 28% that of the uninjured thumb. One-half of the patients could touch the MP of their ring finger, and one-fourth could touch the proximal interphalangeal (PIP) joint. Twenty-one percent had 7 mm or less two-point discrimination, and 38% had between 8 and 20 mm. Eighty percent of both groups were able to perform activities of daily living at 80% of their uninjured side. Grip strength was approximately 84% of that of the uninjured hand in each group. Lateral pinch averaged 68% +/- 26% of that of the normal side in the replant group and 91% + 9% in the amputation group. Work simulator assessment of lateral and three-point pinch was better in the revision group. Scores on Jebsen testing were slightly better for those with replanted thumbs, but in general neither replant nor revision patients functioned as well as did Jebsen's normals.(ABSTRACT TRUNCATED AT 250 WORDS)
对1971年至1985年间111例单纯性、完全性拇指离断患者进行了回顾性研究,以评估再植效果并与截肢修复效果进行比较。对69例成功再植患者和42例接受修复患者进行了常规术后评估。再植组25例和修复组18例返回进行进一步检查,包括访谈和体格检查、日常生活活动测试、Jebsen手功能测试以及BTE工作模拟器的静态和动态测试。90%的再植手术在掌指关节(MCP)和远节指骨近端三分之一之间进行。平均缩短11mm,活动范围为健侧拇指的42%±28%。一半的患者能够触及环指的掌指关节,四分之一的患者能够触及近端指间关节(PIP)。21%的患者两点辨别觉为7mm或更小,38%的患者在8至20mm之间。两组中80%的患者能够以健侧80%的能力进行日常生活活动。每组握力约为健侧手的84%。再植组侧捏力平均为正常侧的68%±26%,截肢组为91%±9%。修复组在工作模拟器上对侧捏和三点捏的评估更好。再植拇指患者的Jebsen测试得分略高,但总体而言,再植患者和修复患者的功能均不如Jebsen测试的正常标准。(摘要截选至250字)